Forum Post: RE: GAS drawing takes approx. 30min to 1 hour for just ploting...
Please try to open ISOMETRIC drawing in vanilla AutoCAD. Add check plot preview performance. Will there be any difference in timing? This will let to determine if performance is related to AutoPlant...
View ArticleForum Post: RE: GAS drawing takes approx. 30min to 1 hour for just ploting...
Dear Artiom, Please let me know what is the meaning of etransmit package in AutoCAD or do you want to say export package? Also please let me know steps for creating etransmit package in AutoCAD. So...
View ArticleForum Post: RE: GAS drawing takes approx. 30min to 1 hour for just ploting...
In AutoCAD go to File Eetransmit , follow steps and save zip package locally. With eTransmit, you can package a set of files for Internet transmission. Easy way to gather related files in one zip...
View ArticleForum Post: RE: OpenPlant Modeler Administrator Training - Complaint
If it is a training officially listed on the LEARNserver you are eligible to participate. http://www.bentley.com/en-US/Training/Products/Offerings/Subscription/default.htm Currently there are no...
View ArticleForum Post: RE: OPM without OPMS in a distributed environment
Shaun, Thank you for your lightening fast reply. Could you please help me understand your third point? 3) When we get the new project database, it will only work if you are using OPMS. This could...
View ArticleForum Post: AutoPlant Isogen error when connected to Equipment Nozzle
When I try to run an isometric of a line connected to and Equipment Nozzle I am getting the error below. It is the same for all nozzle types. Error executing script for component Class = NZEQAX:...
View ArticleForum Post: FROM ACESS TO SQL DBASE
Have recently installed Autoplant Select Series 5. Company recently invested in SQL server. Would like to know the best way to convert to SQL central mode from access distributed
View ArticleForum Post: RE: FROM ACESS TO SQL DBASE
I would suggest the following. 1. Take a project package of your access autoplant project. (using project packager) 2. Restore it as new project using SQL as the database, you would need to think...
View ArticleForum Post: RE: GAS drawing takes approx. 30min to 1 hour for just ploting...
Dear Artiom, Previously it was taking 30min for just plot preview and 35min to create pdf file. After trying your Eetransmit way, its reduce to 20min for plot preview and 22min to create pdf file....
View ArticleForum Post: RE: GAS drawing takes approx. 30min to 1 hour for just ploting...
Thank you for your reply. Would it be possible to get Eetransmit package for testing? As well have you compared timing between ruining Plot preview in vanilla AutoCAD and AutoCAD with loaded...
View ArticleForum Post: RE: GAS drawing takes approx. 30min to 1 hour for just ploting...
Dear Artiom, Uploaded at Bentley's Secure File Upload webpage. Please have a look on it. Waiting for solution.
View ArticleForum Post: RE: AutoPlant Isogen error when connected to Equipment Nozzle
Hello, Could you please let me know what selection type are you using? It seems I have found similar issue that was reported as Trouble Report D-123740. Please try to use workaround from this Trouble...
View ArticleWiki Page: Setting ACIS/Solid Kernel globally from ProSteel Options
Setting ACIS/Solid Kernel globally from ProSteel Options. ACIS = SOLID KERNEL for ProStructures SS4 (08.11.04.42), SS5 (08.11.10.54) and onwards You can have this option set in the ProSteel...
View ArticleForum Post: RE: GAS drawing takes approx. 30min to 1 hour for just ploting...
I have found user's with similar problems in the past. Oftentimes, the issue was that in large projects with many drawings/models referenced in someone had mistakenly used the ATTACH option instead...
View ArticleForum Post: Bentley SpecGen - Specification Generator - Slow loading on Rebuild
Hello,I use Bentley Specification Generator V8i (SELECT series 3) or SpecGen for short. In the SpecGen program. I copied a template Spec in my Project. In the Spec itself; I edited the tables to...
View ArticleForum Post: RE: AutoPlant Isogen error when connected to Equipment Nozzle
Thanks Artiom, That does not work unfortunately. No matter what selection type I use I still get the same problem. I have a second PC running SS4 and this is running fine. Ran a similar iso on this...
View ArticleForum Post: RE: OPM without OPMS in a distributed environment
Shaun "new release of OPM coming in the next few days"....do u have a estimated date? Im about to upgrade to "08.11.09.383" but if a new version is coming in the next few days I think I will wait for...
View ArticleForum Post: RE: OPM without OPMS in a distributed environment
Parijat, We are in the process of building a true Project Database. This will replace all of our current plant databases and allow us to share data between 2D and 3D. Any information added in either...
View ArticleForum Post: RE: OPM without OPMS in a distributed environment
Jojje, The development teams are in their final tests on all of the new OpenPlant products. As for the exact date, I will have to leave that to the developers, I would not want to tie them to a date....
View ArticleForum Post: RE: AutoPlant Isogen error when connected to Equipment Nozzle
So it's either as Isogen issue, in which case there aren't too many good solutions), or its a difference between SS3 and SS4. I would compare the PCF out routines (ebs files found in the...
View Article