Quantcast
Channel: OpenPlant | AutoPLANT
Browsing all 16985 articles
Browse latest View live

Wiki Page: To Save BOM Template for Multiple Query in OpenPlant Reporting

Applies To Product(s): OpenPlant Reporting Version(s): 08.11.09.564 Environment: Windows 7 (64 bit) Area: - Subarea: - Original Author: Rahul Kumar, Bentley Technical Support Group Overview In...

View Article


Wiki Page: How to Get Tag number on Valves

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.470 Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: Original Author: Dinesh Solanki, Bentley...

View Article


Comment on To Assign Separate Level For Component Using Named Expression

Hi Rahul, Can you give me named expression as same as above but only including valve tag rather than only "valve" Currently I'm using following expression for Symbology by spec....

View Article

Comment on How to Assign Levels based on Equipment Type Using Named Expression

Hi Rahul, Can you give me expression line "Tank-Tag No." ? Thank you Regards, Rakesh Rakesh.saka@uk.mwhglobal.com

View Article

Wiki Page: How to Add IsoSheet Information on Piping Components & Supports

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Component Subarea: - Original Author: Rahul Kumar, Bentley Technical Support Group Overview Adding...

View Article


Comment on How to Assign Levels based on Equipment Type Using Named Expression

Hello Rakesh, Thanks for looking in to this. For Equipment Type with Tag, we need to check the possibility, we will get back to you soon on this. -Regards | Rahul Kumar

View Article

Blog Post: CAD Administrators vs IT?

Let me get one thing straight, this isn’t meant as an attack on any one group and I’m not trying to single any group out. This is just my opinion on where I think the effort and skills should come from...

View Article

Wiki Page: To Highlight Components based on Shop or Field Value in OpenPlant...

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.564 Environment: Windows 7 (64 bit) Area: Component Subarea: Graphics Original Author: Rahul Kumar, Bentley Technical Support Group...

View Article


Wiki Page: How to Use the Isometric Cleanup When the Output Format is DWG

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.470 & Above Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley...

View Article


Wiki Page: Bill of Material Description for Bolt, Gasket not Getting...

Applies To Product(s): OpenPlant Isometrics Manager & AutoPlant Modeler Version(s): 08.11.09.458 & 08.11.11.135 Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: Original Author:...

View Article

Forum Post: RE: Autoplant 3d SS5 - Bill of material style & isometric dwg...

Hello Hasnuddin, OPenplant Isometric Manager application is used for generating isometric in AutoPLANT SS5. 1. You can configure your own BOM style by editing 'Report.def' file. This file is located on...

View Article

Wiki Page: Modify Support Tag by Including Unit, Service and LineNumber...

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Component Subarea: - Original Author: Harpreet Singh, Bentley Technical Support Group Background In...

View Article

Wiki Page: Component - OpenPlant Modeler

Component- OpenPlant Modeler See Index: Cannot Update Calculated Bolt Lengths in Description Field Delete/Replace the Flange Assembly in Open Plant Modeler Forcing OPM to Redraw Pipelines According To...

View Article


Forum Post: RE: How to replace already available attributes of the pipeline...

Hello, Could you please provide additional information and some screenshots of how you tried to “import PIPING_NETWORK_SYSTEM” attributes? What version of OpenPlant modeler you are using? Procedure of...

View Article

Wiki Page: Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX & Others Environment: Windows 7 64 bit Area: - Subarea: - Original Author: Bentley Technical Support Group Isometrics...

View Article


Forum Post: AP OPIM - Text Comments location is wrong on fittings

Previously I put text comments on pipe, and they looked OK. However, when I put a comment text on a branch end, such as a plug, it points to a strange location. Originally, thought it might something...

View Article

Wiki Page: Adding Drafter Instructions To Component Data [TN]

Applies To Product(s): AutoPLANT Piping Version(s): 08.11.05.36 Environment: N/A Area: N/A Subarea: N/A Original Author: Jesse Wolfe, Bentley Technical Support Group Overview Although ideally drafters...

View Article


Wiki Page: How to Add Weld Tag as FW/FFW on Isometrics weld in OpenPlant...

Applies To Product(s): OpenPlant Isometric Manager Version(s): 08.11.09.470 & above Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley...

View Article

Wiki Page: Settings/Attributes- OpenPlant Isometrics Manager

Settings/Attributes - OpenPlant Isometrics Manager Settings/Attributes - OpenPlant Isometrics Manager To Discuss various settings desired to output Isometric drawings. See Index: Add New Valve Topworks...

View Article

Wiki Page: Project Database Error ATDB0807 The Database Manager Failed To...

Applies To Product(s): AutoPLANT Piping; SQL Server 2005 Version(s): V8i Environment: N/A Area: N/A Subarea: N/A Original Author: Bentley Technical Support Group Overview Error occurs saving AutoPLANT...

View Article
Browsing all 16985 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>