Forum Post: RE: AP OPIM - String operation/function in OPIM expression
Hi Frank and Rahul, IE_ExcludeSpecBreak option only work partially on my case. A component connecting two different spec in many case is OOS item. We want to two spec break in below image merget to one...
View ArticleForum Post: RE: OpenPlant Orthographics Manager V8i SS5 install issue
Please download build given in the link below and install it. bentley.sharefile.com/d-s0ecb2d164a64198b Please update with your result. Regards, Harpreet
View ArticleForum Post: AP OPIM - Bolt length in BOM
It looks like the bolt length has some length sensitive, some length can output as inches, and some not - remaining in mm. Anything I can do on this? Thanks, Maggie
View ArticleForum Post: RE: Built own piping spec/class
The long description for any component can be modified to be any value however using description builder may have some challenges. Other fields in the spec can bed edited to match the description...
View ArticleForum Post: Specgen problem: mm_jis_jpi fittings list not appear in specgen
Hi Bentley, I'm new user for autoplant 3d ss5. I'm having problem with specgen. i'm using mm_jis_jpi spec for JIS std. I want to view the mm_jis_jpi fitting item in specgen but the item not appear...
View ArticleForum Post: RE: AP OPIM - Bolt length in BOM
Hi Maggie, By design OPIM can handle metric and imperial (diameter and/or length) bolts in the same project/isometric. The diameter and lengths are then displayed in the correct format in the BOM.The...
View ArticleWiki Page: Add New Valve Topworks
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit & Others Area: Processing Subarea: Original Author: Abhijit Bute, Bentley Technical...
View ArticleWiki Page: Add Nozzle Rating and Facing Information in Continuation Nozzle...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 32/ 64 bit Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Technical...
View ArticleWiki Page: Weld Tags Sorting in Numerical and Sequencing Order in OpenPlant...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley...
View ArticleForum Post: RE: AP OPIM - Bolt length in BOM
Thanks for the reply, Frank. This issue can be reproduced by adding a spacer between two flanges. I was supprised that the bolt length conversion between metric and imperial is a simply mapping method...
View ArticleWiki Page: To Update Material, Schedule for Existing Model in OpenPlant Modeler
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.564 Environment: Windows 7 (64 bit) Area: - Subarea: - Original Author: Rahul Kumar, Bentley Technical Support Group Overview To...
View ArticleForum Post: RE: AP OPIM - Bolt length in BOM
Hi Maggie, When metric length bolts an increment of 5 mm should be used. When 6.45mm is specified in the spec you're using quarter inch increments which is a bit strange for a metric length bolt. When...
View ArticleForum Post: RE: AP OPIM - Bolt length in BOM
we are always doing in mix-metric, and 6.35 is using in increment. In some cases, spec databases are provided by client and we have no control on them. In old projects, I did some codes to control pcf...
View ArticleForum Post: RE: I need help creatin an angled pressure relief valve (inlet...
The main issue here is that most of the relief valves do have the correct pressure class but the text format is incorrect. Most ratings in the spec are listed as CL150 the relief valve has their rating...
View ArticleForum Post: RE: OpenPlant Orthographics Manager V8i SS5 install issue
Hi Craig, Did you try the installer provided in above link? Please update with your result. Regards, Harpreet
View ArticleForum Post: RE: Specgen problem: mm_jis_jpi fittings list not appear in specgen
1) How to view in full list for mm_jis_jpi spec using specgen? What is likely happening here is that the first line is pulling all components from the attached catalogs for this spec. Uncheck Expert...
View ArticleForum Post: RE: ProjectWise Logical Set Update KeyIn
What product is being used with Projectwise?
View ArticleForum Post: RE: ProjectWise Logical Set Update KeyIn
HI Joey, I would like to use this key in with microstation V8i, i-model composer and Openplant in near future.. After using the key in message area should show as screen shot attached Regards, Vivek
View ArticleForum Post: PLANTSPACE XM rimref not found, error reading label, mdl command...
Hello everyone, i'm an on-site support guy who prepares and fix PCs for bentley users in Fincantieri. I do not personally use any of the Bentley software, so I apologize if my question is dumb or my...
View ArticleWiki Page: To Trim Piping BOM Reports Template Fields in OpenPlant Modeler
Applies To Product(s): OpenPlant Reporting Version(s): 08.11.09.564 Environment: Windows 7 (64 bit) Area: - Subarea: - Original Author: Rahul Kumar, Bentley Technical Support Group Overview In...