Applies To Product(s): OpenPlant Reporting Version(s): 08.11.09.564 Environment: Windows 7 (64 bit) Area: - Subarea: - Original Author: Rahul Kumar, Bentley Technical Support Group Overview In OpenPlant Modeler, to save BOM template for Multiple Component selection. Problem Description User requirement was to save the multiple component query report to enable them to use it on other projects. As per requirement of the project, different combination of classes may be used to query the report to get the specific property field in the report. Hence modeler desire is to save the query and user it for future projects or to utilize it in different projects or the projects possess different units of measurement (UOM). See steps to resolve the issue. Steps to Resolve Launch OpenPlant Modeler, Select Project unit. Say Metric here. Go to OpenPlant Modeler>Tools>Item Reports. From Piping>Piping Component, select BOM type BOM by Line Number. Right click on it, Select ‘Edit’. Click on browse option for Querying. Select multiple component and hit “save” like shown in below image. Give some logical name to recognize the type of report. Launch another project with a different unit. Reuse same saved file using open option. See Also http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/4352.openplant-reporting Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
↧