Applies To Product(s): OpenPlant Isometrics Manager & AutoPlant Modeler Version(s): 08.11.09.458 & 08.11.11.135 Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Technical Support Group Problem Description During isometric generation of OpenPlant Isometric Manager, Description for gasket and bolt are not getting in isometric it shows as OPM Component. Steps to Resolve Open up the class editor. 2. Open the OpenPLANT_3D.01.04 schema. Ex.C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_METRIC\Config\OpenPLANT\schema 3. Right click and Supplement the OpenPLANT_3D_Supplemental_Isometrics_Isoextractor.01.04 schema 4. Search for the Gasket Class shown below image. 5. Highlight Gasket on the left and go to the properties tab on the right and highlight Description 6. Pick Add/Remove Custom attributes. 7. Find the AutoPLANT_PDW_Property_Map, highlight it and hit the down arrow to add it in. Choose ok. 8. Under the AutoPLANT 3D section, add LONG_DESC in the PropertyName 9. Similar steps need to be done with BOLT class. 10. Save and close the schemas 11. Review the result. Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧