Applies To Product(s): OpenPlant Isometric Manager Version(s): 08.11.09.470 & above Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Technical Support Group Overview To Label Weld tags as FW/FFW using User Labels in OpenPlant Isometrics Manager. Problem Description In Isometrics different weld types are used to understand what exact weld type would be applicable to get specific tagging on it. Following steps will aid user to add weld tag for "field weld" (FW) or "Field Fit Weld" (FFW) to show it on isometrics. This could be realized using both AutoPLANT Modeler and OpenPlant Modeler user with OpenPlant Isometrics Manager. Check below steps described using AutoPLANT Modeler and OpenPlant Isometrics Manager. Steps to Resolve Open Project Administrator and select working Project. Click on Create and modify button to launch OpenPlant Isometrics Manager Configuration dialog. Under "Isometrics Style" Tab click on User labels. Click on Plus "+" button to create a new User label. Add all fields like shown in below image. Generate isometric to review the result. Note: similarly we can define new label for other weld types field fit weld, Tack Field Weld. etc. See Also Check other helpful link on user labels issue: Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧