Applies To Product(s): AutoPLANT Piping; SQL Server 2005 Version(s): V8i Environment: N/A Area: N/A Subarea: N/A Original Author: Bentley Technical Support Group Overview Error occurs saving AutoPLANT models in a SQL Server project where the database has been either upgraded, moved to or created in SQL Server 2005. Project Database Error ATDB0807 The Database Manager Failed To Commit The Current Changes The inconsistency is due to the user log in. SQL Server 2005 is case sensitive. Make sure that the following three occurences of the SQL Server user account name are identical in case. 1. When the user is created via SQL Server. 2. When the user is attached to the database also in SQL Server 3. When the user name is specified in the connection dialog in Project Administrator (also stored in the PROJECT.INI) See Also Product TechNotes and FAQs External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
↧