Quantcast
Channel: OpenPlant | AutoPLANT
Browsing all 16985 articles
Browse latest View live

Forum Post: RE: AUTO PLANT-RUNTIME ERROR

Hello Chuck, Could you please send me the model for testing. Regards Dinesh

View Article


Forum Post: OpenPlant Isometric Manager, orientation label for owlets an tees!

Hello, we are working with OpenPlant Modeler and OpenPlant Isometric Manager. We want to us some orientation output on isometric for our owlets an tees. How could I implement this Label? Thanks for...

View Article


Wiki Page: Plant Design and Engineering - Wiki (fr)

View Article

Wiki Page: Plant Design and Engineering - Wiki (es)

View Article

Wiki Page: Plant Design and Engineering - Wiki (de)

View Article


Forum Post: RE: OpenPlant Isometric Manager, orientation label for owlets an...

Hi, Is it possible to post some snapshot or reference on how you want to see in OpenPlant Isometrics Manager? Or is this only with labeling the attributes to be appear in OpenPlant Isometrics Drawing....

View Article

Forum Post: RE: Custom OPM Element Templates

This helps a lot to understand the connection...I thought the content of the Named Expressions were buried somewhere in the schemas (which I obviously couldn't find). So, looking at this, I don't want...

View Article

Forum Post: RE: OpenPlant Isometric Manager, orientation label for owlets an...

Hello Rahul, attached you could find a screenshot of a pipeline with two weldolets. they have a orientation of 45°. We want to see this information also on isometric as a label!

View Article


File: bellow Bending Stiffness input for AutoPIPE

The Caesar II user's guide: Bending stiffness from EJMA (and from most expansion joint manufacturers) that are used in a finite length expansion joint model should be multiplied by 4 before being used...

View Article


Forum Post: RE: AutoPLANT Error! It won't start. 'unable to read the AT.INI file

I am also experiencing this error. A number of suggested solutions that did not work: 1) Full uninstall of all AutoCAD and AutoPLANT, restart machine, reinstall. 2) Delete registry entries and repair...

View Article

Wiki Page: “Failed to enable AutoPLANT project “************” for OpenPlant”

Applies To Product(s): AutoPLANT Modeler Version(s): 08.11.10.182 Environment: Windows 7 64 bit Area: Subarea: Original Author: Dinesh Solanki, Bentley Technical Support Group Overview AutoPLANT...

View Article

Forum Post: RE: Custom OPM Element Templates

Brent, as the opmodeler.dgnlib is in the project workspace, it is a project level file. I would recommend keeping it simple and just edit the delivered file. I know this breaks with everything you ever...

View Article

Forum Post: RE: Custom OPM Element Templates

Sounds good Shaun...thank you. At CH we have taken the delivered OPM dataset and made an enterprise dataset, thus when we receive updated installs of OPM we can merge in any new content as needed and...

View Article


Forum Post: RE: Custom OPM Element Templates

Brent, Yes, this makes perfect sense. I am quite familiar with most of what you are doing. I get to watch from a careful distance J I am not sure, but I think that if you wanted to replace our Element...

View Article

Forum Post: Default Radius Type

Does anyone know how to change the Radius Type under the AutoFitting tab in the Place Pipe command to Short Radius instead of Long Radius? Several of our pipers have asked whether this can be done and...

View Article


Forum Post: RE: Default Radius Type

Believe it or not, it is in the pcf file. The defaults are Short Radius, Long Radius and 3R, you may change this list as you see fit, although it may actually sort alphabetically, have never really...

View Article

Forum Post: RE: Default Radius Type

Ha this is awesome...I combed through this configuration but my brain never registered this! So, I adjusted the PCF as follows: #---------------------------------------------------------------------- #...

View Article


Forum Post: RE: AutoPLANT Error! It won't start. 'unable to read the AT.INI file

Hello, Is this a new install ? Or some other version of AutoPlant were previously installed on this PC? I have seen this once when AutoCAD was not launched before installing AutoPlant. But reinstating...

View Article

Wiki Page: Installation steps for OpenPlant Isometrics Manager with AutoPLANT...

Background OpenPlant Isometrics Manager can be used with OpenPlant Modeler and AutoPLANT Modeler. During the installation user need to select the provided proper option for each product. Following...

View Article

Comment on How to stretch an AutoPLANT Pipe

Hi, the correct term for this kind of selection in Autocad is "using Crossing Window method". Regards

View Article
Browsing all 16985 articles