Forum Post: RE: AutoPLANT Error! It won't start. 'unable to read the AT.INI file

$
0
0
Hello, Is this a new install ? Or some other version of AutoPlant were previously installed on this PC? I have seen this once when AutoCAD was not launched before installing AutoPlant. But reinstating auto plant using below steps should resolve this: It is recommended to completely uninstall existing AutoPLANT V8i applications before installing AutoPLANT V8i (SELECTseries 4). Please make sure that the below mentioned folders are clean (if exists) before installing AutoPlant. Windows 7 (64 bit) C:\Program Files (x86)\Bentley\Plant V8i\ C:\Program Files (x86)\Common Files\Bentley Shared\Plant V8i\ C:\ProgramData\Bentley\Plant V8i\ As well I would recommend removing these folder while reinstating AutoPlant. As well you could try resetting AutoPlant AutoCAD profile: Please try following: 1.Go to Registry Editor. 2.Remove this key " HKEY_CURRENT_USER\Software\Autodesk\AutoCAD\R18.2\ACAD-A001:409\Profiles\AutoPLANT_SS3_PDW811ACAD_A001_409" 3.Start AutoPlant using desktop shortcut. I hope this will be useful. Regards, Artiom