Forum Post: Re: Isogen Continuing Components Issue

I managed a workaround.. Basically decided to just suppress all supports on continuations since we don't really need to see them anyway,  For any interested, in the SptOut.ebs, I added the following...

View Article


Image may be NSFW.
Clik here to view.

Wiki Page: How to Suppress supports on Isogen Continuations

 Document InformationDocument Type: TechNoteProduct(s): AutoPLANT AutoIsogenVersion(s): V8i SS4Original Author: UserOverviewAfter fieliding complaints on Isogen continuations and supports for a couple...

View Article


Forum Post: Re: Best practice guide to handle future or existing equipment in...

Tony,I tried the second approach.  It only works on Element Information dialog box.  It won't work during placement or in items browser --> Edit or Update Property.Something wrong with my setup?  (...

View Article

Forum Post: Re: Shows : evaluation version of ComponentOne:VSFlexGrid8(Light)...

Yes Jesse, unfortunately it is still there in SS4.

View Article

Forum Post: Re: Bentley Data Manager - Import from Excel Sheet

Thank you for the feedback Eric, glad to hear it worked . Regards, Artiom

View Article


Image may be NSFW.
Clik here to view.

Wiki Page: Bentley Navigator

View, Analyze, and Augment Project InformationBentley Navigator V8i is the dynamic collaboration software used by infrastructure teams to interactively view, analyze, and augment project information....

View Article

Image may be NSFW.
Clik here to view.

Wiki Page: Reducers in Cable Tray module are drawn upside down.

   Applies To    Product(s):AutoPLANT Piping Version(s):08.11.09.140 Environment: Windows 7 64 bit Area: Component Subarea: Placement Original Author:Artiom Jakubovic, Bentley Technical Support Group...

View Article

Forum Post: Re: OpenPlant Modeler and OpenPlant PID iModels

Spyker,The process involves Publishing the i-model from within PowerPID - i know you did this so just bear with me.1. Publish the i-model the data should be there. If it is not make sure that all paths...

View Article


Image may be NSFW.
Clik here to view.

Forum Post: How do we Bulk load company standard services into OPM SS5 and...

How do we bulk load our company standard services that we used in PIPE_SYMB table of PSDSXM to OPM SS5?Second challenge is that once we have these standard services loaded in OPM and want to create new...

View Article


Image may be NSFW.
Clik here to view.

Forum Post: Re: OpenPlant Modeler and OpenPlant PID iModels

Hi TonyThanks for the above pointers.  To be sure I reinstalled all applications and now have the following:One of my projects seems to be broken and cannot publish iModels correctly.  I used OOTB and...

View Article

Image may be NSFW.
Clik here to view.

Wiki Page: PCF Export Limitations [FAQ]

   Applies To    Product(s):AutoPLANT AutoISOGEN Version(s):V8, XM, V8i Environment: N/A Area:  Subarea: N/A Original Author:Artiom Jakubovic, Bentley Technical Support Group          At this time,...

View Article

Image may be NSFW.
Clik here to view.

Wiki Page: AutoPLANT AutoISOGEN

Key:CS – Client Server ArticleFAQ –  Frequently Asked QuestionsTB – Technical Bulletin TN – TechNoteVID – SELECTsupport VideoIsometric Drawing SoftwareThe Import/Export feature supports output to a...

View Article

Forum Post: Re: OPPID Data in AutoCAD

Thank you Tony...that does help as it confirms what we suspected.

View Article


Forum Post: Re: How do we Bulk load company standard services into OPM SS5...

Hi Justinas, When I say bulk import OPM services - I am talking about a new feature of importing services through text file, this feature - Import project objects (Unit, Service) through text file is...

View Article

Image may be NSFW.
Clik here to view.

Forum Post: isogen not using custom skey for dummy legs

Hello!(AutoPLANT V8i SS4, AutoCAD 2012, SQL 2008)I am having an issue where isogen ignores the custom symbol I have created for dummy legs.  In the image on the left below, you will see the expected...

View Article


File: Sample text files to import Unit, Service, Pipeline instances to an...

View Article

Image may be NSFW.
Clik here to view.

Forum Post: Re: How do we Bulk load company standard services into OPM SS5...

Hello Parijat,I have created a knowledge entry on how to use that new  import feature in OPM SS5. You can find it here: communities.bentley.com/.../8569.aspxPlease, let me know if it is clear enough...

View Article


Image may be NSFW.
Clik here to view.

Wiki Page: How to import Unit, Service, Pipeline instances from a text file...

   Applies To    Product(s):Bentley OpenPlant Modeler Version(s):08.11.09.278 Environment: N/A Area: Tasks Subarea: Piping Original Author:Justinas Lipnickas, Bentley Technical Support Group...

View Article

Image may be NSFW.
Clik here to view.

Wiki Page: Cannot Revise I&W Drawings - You do not have Permission for this Task

   Applies To I&W; Layout Designer; Revision Control   Product(s): Version(s): Environment: 08.11.09.140 Area: Document Revision;Security Subarea:  Original Author:Bentley Technical Support Group...

View Article

Image may be NSFW.
Clik here to view.

Wiki Page: How do I move a P&ID drawing to another Project?

   Applies To Exchange Drawings   Product(s):AutoPLANT P&ID Version(s):08.11.09.140 Environment: N/A Area:  Subarea:  Original Author:Bentley Technical Support Group           How to move...