Forum Post: Re: Isogen Continuing Components Issue
I managed a workaround.. Basically decided to just suppress all supports on continuations since we don't really need to see them anyway, For any interested, in the SptOut.ebs, I added the following...
View ArticleWiki Page: How to Suppress supports on Isogen Continuations
Document InformationDocument Type: TechNoteProduct(s): AutoPLANT AutoIsogenVersion(s): V8i SS4Original Author: UserOverviewAfter fieliding complaints on Isogen continuations and supports for a couple...
View ArticleForum Post: Re: Best practice guide to handle future or existing equipment in...
Tony,I tried the second approach. It only works on Element Information dialog box. It won't work during placement or in items browser --> Edit or Update Property.Something wrong with my setup? (...
View ArticleForum Post: Re: Shows : evaluation version of ComponentOne:VSFlexGrid8(Light)...
Yes Jesse, unfortunately it is still there in SS4.
View ArticleForum Post: Re: Bentley Data Manager - Import from Excel Sheet
Thank you for the feedback Eric, glad to hear it worked . Regards, Artiom
View ArticleWiki Page: Bentley Navigator
View, Analyze, and Augment Project InformationBentley Navigator V8i is the dynamic collaboration software used by infrastructure teams to interactively view, analyze, and augment project information....
View ArticleWiki Page: Reducers in Cable Tray module are drawn upside down.
Applies To Product(s):AutoPLANT Piping Version(s):08.11.09.140 Environment: Windows 7 64 bit Area: Component Subarea: Placement Original Author:Artiom Jakubovic, Bentley Technical Support Group...
View ArticleForum Post: Re: OpenPlant Modeler and OpenPlant PID iModels
Spyker,The process involves Publishing the i-model from within PowerPID - i know you did this so just bear with me.1. Publish the i-model the data should be there. If it is not make sure that all paths...
View ArticleForum Post: How do we Bulk load company standard services into OPM SS5 and...
How do we bulk load our company standard services that we used in PIPE_SYMB table of PSDSXM to OPM SS5?Second challenge is that once we have these standard services loaded in OPM and want to create new...
View ArticleForum Post: Re: OpenPlant Modeler and OpenPlant PID iModels
Hi TonyThanks for the above pointers. To be sure I reinstalled all applications and now have the following:One of my projects seems to be broken and cannot publish iModels correctly. I used OOTB and...
View ArticleWiki Page: PCF Export Limitations [FAQ]
Applies To Product(s):AutoPLANT AutoISOGEN Version(s):V8, XM, V8i Environment: N/A Area: Subarea: N/A Original Author:Artiom Jakubovic, Bentley Technical Support Group At this time,...
View ArticleWiki Page: AutoPLANT AutoISOGEN
Key:CS – Client Server ArticleFAQ – Frequently Asked QuestionsTB – Technical Bulletin TN – TechNoteVID – SELECTsupport VideoIsometric Drawing SoftwareThe Import/Export feature supports output to a...
View ArticleForum Post: Re: OPPID Data in AutoCAD
Thank you Tony...that does help as it confirms what we suspected.
View ArticleForum Post: Re: How do we Bulk load company standard services into OPM SS5...
Hi Justinas, When I say bulk import OPM services - I am talking about a new feature of importing services through text file, this feature - Import project objects (Unit, Service) through text file is...
View ArticleForum Post: isogen not using custom skey for dummy legs
Hello!(AutoPLANT V8i SS4, AutoCAD 2012, SQL 2008)I am having an issue where isogen ignores the custom symbol I have created for dummy legs. In the image on the left below, you will see the expected...
View ArticleForum Post: Re: How do we Bulk load company standard services into OPM SS5...
Hello Parijat,I have created a knowledge entry on how to use that new import feature in OPM SS5. You can find it here: communities.bentley.com/.../8569.aspxPlease, let me know if it is clear enough...
View ArticleWiki Page: How to import Unit, Service, Pipeline instances from a text file...
Applies To Product(s):Bentley OpenPlant Modeler Version(s):08.11.09.278 Environment: N/A Area: Tasks Subarea: Piping Original Author:Justinas Lipnickas, Bentley Technical Support Group...
View ArticleWiki Page: Cannot Revise I&W Drawings - You do not have Permission for this Task
Applies To I&W; Layout Designer; Revision Control Product(s): Version(s): Environment: 08.11.09.140 Area: Document Revision;Security Subarea: Original Author:Bentley Technical Support Group...
View ArticleWiki Page: How do I move a P&ID drawing to another Project?
Applies To Exchange Drawings Product(s):AutoPLANT P&ID Version(s):08.11.09.140 Environment: N/A Area: Subarea: Original Author:Bentley Technical Support Group How to move...
View Article