Forum Post: Error when opening drawing
When I open a drawing containing a ferrule and a length of pipe, I get the following error message:"Command: Error: PUTL0403: AT_TRI_FERRULE requires a traversal"What does this mean?
View ArticleForum Post: OpenPlant Modeler SS5 scans all attached reference files when...
Hi,I am using OPM SS5 (08.11.09.278) with or without ProjectWise.When I click for instance 90 deg elbow command, OPM starts loading all reference file (simple 3d mstn files made with latest v8i...
View ArticleForum Post: Re: OPPID Data in AutoCAD
Brent,First - modify the PID.cfg file by locating the section below and editing it to include the OpenPlant_PID schema.#Specify schemas that are to be used for Publish...
View ArticleForum Post: Re: V8i ss3 P&ID settings.dbf to ss4 format db3
Dinesh,Thanks for the reply. We have run Integrity Check on the projects.I think we are not talking about the right file here.We are looking to use the ss3 settings.dbf for P&ID from...
View ArticleWiki Page: AutoPLANT P&ID
Key:CS – Client Server ArticleFAQ – Frequently Asked QuestionsTB – Technical Bulletin TN – TechNoteVID – SELECTsupport VideoAn Indispensible Tool for Organizations That Need to Create Intelligent...
View ArticleWiki Page: Auto Plant Alert : This drawing is an export copy...
Applies To Product(s):AutoPLANT P&ID Version(s):XM, V8i, V8 Environment: N/A Area: General Subarea: Original Author:Artiom Jakubovic, Bentley Technical Support Group Usually this...
View ArticleForum Post: Re: How do we Bulk load company standard services into OPM SS5...
Justinas, Thank you very much for creating a knowledge entry on how to use that new import feature in OPM SS5, I am sure it will help a lot of people. The sample files that you sent did work for me...
View ArticleForum Post: Re: OPPID Data in AutoCAD
Thanks Tony...much closer as I'm now seeing all the data being published except for Major and Minor pipeline (from my test file). I'm still getting two errors as shown below. I will keep...
View ArticleWiki Page: Browse Limit in PowerPID tag browse dialog – hits limit when tags...
Applies To Tag Browse Dialog Product(s):OpenPLANT PowerP&ID Version(s):08.11.10.38 and greater Environment: N/A Area: Subarea: Original Author:Bentley Technical Support Group...
View ArticleForum Post: Re: isogen not using custom skey for dummy legs
Hello Jesse, Could you please upload related files. Have you creed new skey for AT_SUPPORT_DUMMY or edited default one ? If new, what parent symbol was used?Have you tried to compare PCF from...
View ArticleForum Post: Re: Error when opening drawing
I'm sorry but it does not happen now! It seems to be ok.Tom
View ArticleForum Post: Why I can't synchronise SPECS in IsoExtractor manager?
Hi all, I was doing some ISO drawing customize job.But I got a problem in synchronise SPECS in IsoExtractor manager.I've tried to leave only one record in my PIPE_PIPE_SPEC,inorder to see what...
View ArticleForum Post: Re: V8i ss3 P&ID settings.dbf to ss4 format db3
Settings.dbf is replaced with settigns.db3 in SS4.If you have made some customizations to Settings.dbf you would need to upgrade the settings.dbf to settings.db3.Exe in the location below will help...
View ArticleForum Post: Re: HOW TO CREATE USER DEFINED SUPPORT
Please see below a link which will help you with the steps.communities.bentley.com/.../4265.aspx
View ArticleForum Post: Re: How to convert .dwg 3d model into .dgn file
Could you please explain a bit more what kind of functionality would you like. Do you just want to convert dwg to a dgn without any intelligence? Or do you want to convert AutoPLANT file to an...
View ArticleWiki Page: AutoPLANT Piping
Key:CS – Client Server ArticleFAQ – Frequently Asked QuestionsTB – Technical Bulletin TN – TechNoteVID – SELECTsupport VideoAutoCAD-Based Piping Design and Modeling SoftwareAutoPLANT Piping gives you...
View ArticleWiki Page: Exception in at_Dialog_display ARX Command
Applies To Product(s):AutoPLANT Piping Version(s):08.09.04.47 Environment: N/A Area: Processing Subarea: Specs Original Author:Artiom Jakubovic, Bentley Technical Support Group Exception...
View ArticleForum Post: Re: WHAT DO YOU HAVE TO DO TO EDIT USER EQUIPMENT?
You can edit the equipment dimesnions and shapes by double clicking on the equipment or right click edit component.However, if you want to modify more for the equipment appearance. Place the modified...
View Article