Wiki Page: Reducers in Cable Tray module are drawn upside down.

Image may be NSFW.
Clik here to view.

  
 Applies To 
  
 Product(s):AutoPLANT Piping
 Version(s):08.11.09.140
 Environment: Windows 7 64 bit
 Area: Component
 Subarea: Placement
 Original Author:Artiom Jakubovic, Bentley Technical Support Group
  

 

 

 

 

 

 

 

Problem Description

Reducers in Cable Tray module are drawn upside down. Filed as Trouble Report D-125805

Image may be NSFW.
Clik here to view.

Steps to Resolve

Open following files for Straight, Left Hand, Right Hand Reducers - sreducer.ebs, lhredcr.ebs, rhredcr.ebs (C:\Program Files (x86)\Bentley\Plant V8i\Modules\CableT\piping\draw)

Find at_CabCreate_Boundary function that is used to draw Boundaries

Go to ‘\\Create a path to extrude along sections (three are two of them)

Change obj = at_CADLine_create (cpUp, shapePts(7)) to obj = at_CADLine_create (shapePts(7), cpUp) in one section and

obj = at_CADLine_create (cpUp, shapePts(6)) line to obj = at_CADLine_create (shapePts(6), cpUp) in another section

The files with above changes can be downloaded here Ebs files