Wiki Page: Which OpenPlant products are supported by Bentley OpenPlant...
Applies To Product(s): OpenPlant Project Administrator Version(s): V8i Environment: N\A Area: N\A Subarea: N\A Original Author: Brandon Moberg, Bentley Product Advantage Group Bentley OpenPlant Project...
View ArticleWiki Page: How to Get AutoPLANT Weld IDs in OpenPlant Isometrics Manager
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit & Others Area: Processing Subarea: Original Author: Kestutis Mitkus, Abhijit Bute, Bentley...
View ArticleForum Post: COG calculation in AutoPLANT
Recently, I was asked to calculate central weight point of whole model and I did a search on it. It looks like Isogen have ability to do it but involve a whole bunch of setup and is by line. Another...
View ArticleWiki Page: Weld Tags Sorting in Numerical and Sequencing Order in OpenPlant...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley Product...
View ArticleWiki Page: Settings/Attributes- OpenPlant Isometrics Manager
Settings/Attributes - OpenPlant Isometrics Manager Settings/Attributes - OpenPlant Isometrics Manager To Discuss various settings desired to output Isometric drawings. See Index: Add New Valve Topworks...
View ArticleComment on Error Document Is Already Registered In Document Register With...
AutoPlant Modeler SS7: This particular error, that I had never seen until 2 days ago keeps happening with annoying regularity now. I created a completely new model using Document Manager, inserted a...
View ArticleForum Post: RE: COG calculation in AutoPLANT
Hello Maggie, Do you need the COG calculation for each pipeline in OpenPlant Isometrics Manager? There were some discussion held to get that implemented in OpenPlant Isometrics Manager. Currently it...
View ArticleForum Post: RE: COG calculation in AutoPLANT
Hello Maggie, You can use the options from Autoplant piping, and use the report generator, than you can calculate the c.o.g. (empty/ ful) Regards, Ber de Koning
View ArticleForum Post: RE: Error : Field:[VNUM] value has length that does not fit in...
Hello Tomasz, Yes, the default value should be changed. Regards Dinesh
View ArticleWiki Page: How to setup Vision/Document Manager to work with OpenPLANT P&ID
Applies To Product(s): OpenPlant PID Version(s): 08.11.10.xxx Environment: Windows 7 64 bit Area: Installation-Configuration Subarea: Original Author: Bentley Technical Support Group Introduction By...
View ArticleForum Post: RE: OPSE Deployment with ProjectWise integration [OPSE...
I have followed the steps outlined in the help files and now I have a few questions about how OPSE works with ProjectWise compared to other Bentley products. We mainly use Microstation and BRCM with...
View ArticleWiki Page: How to Skip THREAD or SOCKET Weld IDs in OpenPlant Isometric Manager
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit & Others Area: Processing Subarea: Original Author: Kestutis Mitkus, Bentley Product...
View ArticleForum Post: Textnodes.txt SQL Connection Criteria
I'm in the process of setting up OPIM to harvest database information from the AutoPLANT Process table as per the topic link below....
View ArticleForum Post: RE: Error : Field:[VNUM] value has length that does not fit in...
Hello Dinesh, after VNUM change drawing convertion went smoothly. Unfortunatelly I'm facing problems with TAG numbers now: After saving and trying to rename TAG I get following DB error: regards Tomek
View ArticleComment on Error: Publish i-model is not available. Please install AutoPLANT...
hi, i have the same issue, i follow Dineshs instructions to uninstall and reinstall i-model Composer, but i still get the same message(Publish i-model is not available. Please install AutoPLANT i-model...
View ArticleWiki Page: Mating Flange Orients in Wrong Direction when Output as DWG in...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.458 Environment: Windows 7 )64 bit) Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Product Advantage...
View ArticleForum Post: RE: Textnodes.txt SQL Connection Criteria
Hi Tyler, www.connectionstrings.com provides a good source for basically all database connection strings. To know which 32 bit ODBC drivers are available on your system start this program:...
View ArticleForum Post: OPM Pipeline Manager Not Updating with Calculated Pipeline Property
I am running OpenPlant Modeler 08.11.09.440. I have a property (SERVICE_GROUP) that is populated in the CREATE PIPELINE dialog by a calculation; in this case, an sql query. When I display the Pipeline...
View ArticleForum Post: RE: OPM Pipeline Manager Not Updating with Calculated Pipeline...
I am running OpenPlant Modeler 08.11.09.440. I have a property (SERVICE_GROUP) that is populated in the CREATE PIPELINE dialog by a calculation; in this case, an sql query. When I display the Pipeline...
View ArticleForum Post: RE: OPM Pipeline Manager Not Updating with Calculated Pipeline...
Hello Warren, For new property created on pipeline tag, you need to set parser expression as well to enable it to edit it later. You may check below wiki article for your help....
View Article