Wiki Page: Fixing SPEC_CHANGE Cell file in OpenPlant Isometrics Manager
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: - Original Author: Rahul Kumar, Bentley Technical Support...
View ArticleWiki Page: How to calculate the Bottom of Pipe (BOP) in OPM
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Properties Subarea: Original Author: Harpreet Singh, Bentley Technical Support Group Introduction...
View ArticleForum Post: RE: Can we have two OPM versions running on the same PC?
The two versions will be OPM versions are 8.11.09.395 and 08.11.09.440
View ArticleForum Post: RE: Can we have two OPM versions running on the same PC?
Consider a scenario where two different versions of OPM are customized differently for two different projects and the user might have to switch between the two projects(eventually versions) on the same...
View ArticleWiki Page: How to Enable OpenPlant Isometrics Manager to Read AutoPLANT Spool...
Applies To Product(s): OpenPlant Isometric Manager Version(s): 08.11.09.470 Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: Original Author: Dinesh Solanki, Bentley Technical Support...
View ArticleWiki Page: How to Change Isometric Output Drawing Name Format
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: - Original Author: Rahul Kumar, Bentley...
View ArticleWiki Page: Error:[5] Unable to Place symbol when use custom seed file...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Technical Support...
View ArticleWiki Page: Setting Border Size to Avoid Clashes with Pipeline in Isometrics...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: - Original Author: Rahul Kumar, Bentley...
View ArticleForum Post: RE: OPIM Label (PartID, CutID, etc) offset in isometrics
Justinas, Is there any update on this? Anyway to control the offset distance of the dimensions or labels in OPIM? Thanks.
View ArticleForum Post: RE: OPIM Label (PartID, CutID, etc) offset in isometrics
Pipeing labels are still placed close the pipe without controls to offset them and the insulation is still an issue and in development to be fixed. However item labels that are on a leader can be...
View ArticleWiki Page: How to add FUSION_WELD joint in OPM
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Schema Subarea: N/A Original Author: Harpreet Singh, Bentley Technical Support Group Introduction...
View ArticleWiki Page: Settings/Attributes- OpenPlant Isometrics Manager
Settings/Attributes - OpenPlant Isometrics Manager Settings/Attributes - OpenPlant Isometrics Manager To Discuss various settings desired to output Isometric drawings. See Index: Add New Valve Topworks...
View ArticleWiki Page: Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX & Others Environment: Windows 7 64 bit Area: - Subarea: - Original Author: Bentley Technical Support Group Isometrics...
View ArticleForum Post: RE: Can we have two OPM versions running on the same PC?
Hello Parijat, Please note side by side installation is not allowed in OpenPLANT Modeler . I hope this anwers your query. Please let us know if you have any doubts. Regards Dinesh
View ArticleForum Post: RE: Can we have two OPM versions running on the same PC?
I was of the same opinion. Just wanted to hear this straight from Horses mouth(Bentley). Thanks Dinesh.
View ArticleWiki Page: Tool for converting AutoPLANT DBF files to Db3 format
Product(s): AutoPLANT P&ID Version(s): AutoPLANT V8i Environment: Windows 7; 64 bit Area: General Subarea: Original Author: Dinesh Solanki, Bentley Technical Support Group Background Settings.dbf...
View ArticleWiki Page: How to Format Number Property in IsoSheet Name
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: - Original Author: Rahul Kumar, Bentley Technical Support...
View ArticleForum Post: RE: Number format in OpenPLANT Modeller
Hello Spyker, I know this one is the oldest you had in a queue. But thought to reply on this note. You can find similar wiki on this. Have a nice day! Regards, Rahul Kumar
View ArticleComment on Where Has All the Training Gone?
Pluralsight have a whitepaper "KEEPING UP TO SPEED: How a new learning mindset is transforming today’s workplace" about issues like this. They present an case for a 70:20:10 framework, where improving...
View ArticleForum Post: RE: OpenPlant PID "missingfields.xml"
Hello Alain, Could you please provide additional information and some screenshots of this issue? If you are getting errors during the synchronization process, could you please post them here? How are...