Forum Post: RE: AUTO PLANT-LOCATION POINT
The only reason it still asks for the coordinate and elevation is because when location point is turned on you can still bypass it to use some other coordinate. So basically if location points was...
View ArticleForum Post: RE: Open Plant Model Server reference out piping with VBA
Ah that makes more sense on why it was doing what it was. So then if we were to set Pipeline as a root it should let you reference out the whole system pipeline correct? Thank you for all you...
View ArticleForum Post: RE: AUTO PLANT-EQUIPMENT LOCATION
Hello CAdTech, Unfortunately, there is not a option to get the equipment co-ordinates. Regards Dinesh
View ArticleForum Post: RE: AUTO PLANT-EQUIPMENT COORDINATE
hello CAdTech, I tested the steps at my end and could move the pump 3' below. Did you use "foot" mark on 3'. If you had left it off, it would only move 3 inches and which could be hardly seen. I hope...
View ArticleForum Post: RE: AUTO PLANT-EQUIPMENT "BASE" POINT
Hello CAdTech, The only way to know the coordinates is using the ID command and get the elevation. You could also hover over the point on the screen and the coordinates show up down in the lower left...
View ArticleForum Post: RE: Open Plant Model Server reference out piping with VBA
Well, setting pipeline as a root node might not be what you really need here. It would just basically show Pipeline as a node in the OPMS browser right under the ZEC_Corp project, like it's with Area,...
View ArticleForum Post: RE: AUTO PLANT-WORK AREA
hello CADTech, Notice in the RWA file the paths are all like this XREF=..\Standards\AT_PIPE1.DWG Whereas, they should look something like this XREF=C:\...\...\Standards\AT_PIPE1.DWG Where...
View ArticleForum Post: RE: Open Plant Model Server reference out piping with VBA
I had tried that, and this might be a setup on our end that needs to be fixed, but it would never complete the process when I tried to go to that level and reference out all. It would sit and crunch...
View ArticleForum Post: RE: AUTO PLANT-EQUIPMENT PLACEMENT
Hello CADTech, I would name my location points something relevant to the equipment I am placing. So Pump100 would relate to PMP-100 pump. That is really the only way to do it. If you name them general...
View ArticleForum Post: RE: Open Plant Model Server reference out piping with VBA
Hmm. And about how many piping components do you have under that node? Might be it is reaching a limit and that's why you get the exception. Which version of OPMS/OPM are you currently running? There...
View ArticleForum Post: RE: AUTO PLANT-UNITS SETTING
The units are set when you create the project in Project Administrator imperial, metric or mixed metric. Creating a project in imperial files will use inches, feet, metric will use millimeters, etc.....
View ArticleForum Post: RE: Open Plant Model Server reference out piping with VBA
Justnas, We are currently using OPM version 415 and OPMS version 414. I too tried to reference out by system and received the same error and when I looked at the log files on the server they weren't...
View ArticleForum Post: RE: Open Plant Model Server reference out piping with VBA
I did it manually and this is what it referenced out. like Brian said, There is hardly any pipe lines/ components in this system. === Reference Out Command Initiated === Sending Command to create...
View ArticleForum Post: RE: AUTO PLANT-WORK AREA INSERTION POINT
Hello CADTech, I see you have multiple selections, could try to select one reference drawing at a time and change the insertion point to see if it works? Regards Dinesh Solanki
View ArticleForum Post: Autoplant Valve Topworks Orientation in Isogen
Hi, When I produce an isometric with a valve in the line the valve topworks are shown but there is no note to say what is the topworks orientation (North, South, East, West, Up, Down etc). When I have...
View ArticleForum Post: RE: Open Plant Model Server reference out piping with VBA
The first thing I would try if getting this error message would be restarting the modelserver service
View ArticleForum Post: I-model export - Level state on/off
HI, I'm using Openplant modeller to export I-model so we can review in Navigator. The problem is when exporting I-model from OPM model all levels are on but after exported I-model open in a Navigator...
View ArticleForum Post: RE: Open Plant Model Server reference out piping with VBA
So in this case it does seem that most likely issue of not being able to reference out by System is due to some issues in your Workspace configuration. As you have added some additional associated...
View ArticleForum Post: RE: AUTO PLANT-WORK AREA INSERTION POINT
The issue with the xref. was in using relative paths, having the relative path box checked. The xref worked after un-checking that box. As far as insertion point, I could set and pick on screen but...
View Article