Quantcast
Channel: OpenPlant | AutoPLANT
Browsing all 16985 articles
Browse latest View live

Wiki Page: Add Elevation in Tooltip

      Applies To        Product(s): AutoPLANT Piping   Version(s):  AutoPLANT V8i /AutoPLANT Modeler   Environment:  Windows 7 32 bit, Windows 7 64 bit   Area:  Component   Subarea:  N/A   Original...

View Article


Comment on OPPID Flow Arrow Location and Spacing

I'm trying to get this to work to have the flow arrow at the vertices, it seemed to move it closer but still not at the vertices. In reading the steps is it impling that SPACING_NONE is a class that...

View Article


Forum Post: AUTO PLANT-UNITS SETTING

Hello, I am learning Auto Plant V8i and following the Bentley Learn server Plant Design Fundamentals.  I noticed my units not set correctly and an xref not scaled correctly.  As part of the work space...

View Article

Forum Post: AUTO PLANT-WORK AREA

Hello, I am learning Auto Plant V8i and following the Bentley Learn server Plant Design Fundamentals.  I have set-up a work area and added x-referenced files.  However, the xrefs did not appear, so...

View Article

Forum Post: AUTO PLANT-WORK AREA INSERTION POINT

Hello, I am learning Auto Plant V8i and following the Bentley Learn server Plant Design Fundamentals. The white box that defines my work area is not centered on my reference files.  If I try to change...

View Article


Forum Post: AUTO PLANT-EQUIPMENT LOCATION POINT

Hello, I am learning Auto Plant V8i and following the Bentley Learn server Plant Design Fundamentals. I have placed so,e equipment and want to manually move and place it.  If I manually move the...

View Article

Forum Post: AUTO PLANT-EQUIPMENT REFERENCE POINT PLACEMENT

Hello, I am learning Auto Plant V8i and following the Bentley Learn server Plant Design Fundamentals. I have placed so,e equipment and want to manually move and place it.  If I manually move the...

View Article

Forum Post: Is there a way to optimize OPM specs(.mdb files) or compress them...

We have a team working on OPM piping specs and currently have roughly 30+ files (of size 1.2GB), this might go up to 45+ pipe specs(one .mdb file per spec) and might have more than 2GB size for these...

View Article


Forum Post: RE: AUTO PLANT-EQUIPMENT REFERENCE POINT PLACEMENT

Hello CADTech, You should edit the "location points" to to move the equipment instead of move command. Also, you can add multiple location points so that you have multiple co-ordinates. I hope thois...

View Article


Forum Post: RE: AUTO PLANT-EQUIPMENT LOCATION POINT

Hello CADtech, Could you please let us know what you mean by insertion point the point. If you mean the white point  on the equipment or the green point? Incase, you mean the green points please do...

View Article

Forum Post: RE: AUTO PLANT-WORK AREA

Hello CADTech, Either way works for x-ref files. The purpose of the RWA is to save designers time and increase productivity. Also, RWA is a file which will help you load multiple x-ref's. I guess...

View Article

Forum Post: RE: AUTO PLANT-WORK AREA INSERTION POINT

Hello CADTech, Do you mean you cannot change the insertion point when membership status is set to Non-member? Please note Non-Member : When this option is selected, the referenced drawings are not...

View Article

Wiki Page: How to make associated items editable in OPPID

      Applies To        Product(s): Bentley OpenPlant PowerPID   Version(s): 08.11.10.427   Environment:  Windows 7 64 bit   Area:  Properties   Subarea:    Original Author: Harpreet Singh, Bentley...

View Article


Wiki Page: Add (Misc.Attachments) Floor Opening class in OPIM Schema.

      Applies To        Product(s): Bentley OpenPlant Isometrics Manager   Version(s): 08.11.09.417   Environment:  Windows 7 32 bit, Windows 7 64 bit   Area:  Settings/Attributes   Subarea:...

View Article

Comment on OPPID Flow Arrow Location and Spacing

the SPACING_NONE class is in the PID schema. If you simply edit the default flow arrow class - SPACING_CLASSNAME property and either edit the Property Custom Attribute or add it and set the Default...

View Article


Forum Post: SQL 2005 TO SQL 2008

Hi, I have an AutoPLANT V8i SS4  project that was originally created using a SQL 2005 database. I want to export this project and create a new one using SQL 2008. Is is OK to move a project from SQL...

View Article

Forum Post: AUTO PLANT-EQUIPMENT COORDINATE

Hello, I am learning Auto Plant V8i and following the Bentley Learn server Plant Design Fundamentals. I have placed a pump and have rotated my view to look at the "right" side view using the WCS...

View Article


Forum Post: AUTO PLANT-LOCATION POINT

Hello, I am learning Auto Plant V8i and following the Bentley Learn server Plant Design Fundamentals. I am placing equipment by location points, and have that option checked-on in the Drawing...

View Article

Forum Post: RE: AUTO PLANT-WHITE NODE

The white box are the insertion point of the nozzles.

View Article

Forum Post: RE: AUTO PLANT-LOCATION POINT

Hello CADTech, When you define a location point and select it while placing equipment then the default location is what is defined in location point. Now, the prompt to select coordinates etc. is just...

View Article
Browsing all 16985 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>