Applies To Product(s): Bentley OpenPlant PowerPID Version(s): 08.11.10.427 Environment: Windows 7 64 bit Area: Properties Subarea: Original Author: Harpreet Singh, Bentley Technical Support Group To make the associated items editable under plant tab of PID_DOCUMENT dialog in OPPID. Background Currently user can't edit the associated items since the edit button is disabled in PID_DOCUMENT dialog and therefore user has no option to edit the associated items. User has to remove the association and create a new association. Steps to Accomplish Modify the PCF file Open the Project PCF file in notepad. Add this configuration variable _BMF_ALLOW_EDIT_OF_ASSOCIATED_ITEM=1 anywhere in PCF file and save it. Launch OPPID and open the PID_DOCUMENT dialog from Settings Drawing. In PLANT tab you will see the EDIT button is enabled
↧