Forum Post: RE: Open Plant Model Server reference out piping with VBA
Hello Mark, Could you please explain a bit more on what is it exactly you would try to do. Do you want to have some easy/automated way to reference out all of the pipelines in the server to a model?...
View ArticleForum Post: RE: Open Plant Model Server reference out piping with VBA
Justinas, What I am looking to do would to have it reference out all piping related to one system. Then we can make master reference files for each of the systems that can be shared with other...
View ArticleForum Post: RE: Open Plant Model Server reference out piping with VBA
Hmm, and just using higher level of relationship to reference everything from some Unit/Service by just right click on it in the same manner as with pipelines would not accomplish the same goal? You...
View ArticleForum Post: RE: Troubles with flattener
Hmm.. Might want to try to rengerate that viewport. Another trick I use occasionally is to create a new drawing, reference in all the drawings needed, then right click on a layout and use 'From...
View ArticleForum Post: Data Manager 'Filter Builder'
Hi, When using DataManager's 'Filter Builder' to filter on equipment types for example, the value list returned contains as many times the equipment types as there are equipment of each type. Is...
View ArticleForum Post: Sir Edward Grey, the British foreign secretary
Back then, as hostilities loomed, , famously remarked: “The lamps are goi Free Google play $25 Gift Card Free Google play $5o Gift Card Google play gift card generator Google play gift card generator...
View ArticleForum Post: RE: Export a PXF
I tried 4 times consecutively without error.. I'll have to defer to the Support guys on this one, sorry Alex.
View ArticleForum Post: RE: Export a PXF
Hello Alex, I have also tried to export the PXF from the model attached a few times, and it does not give any error for me in AutoPLANT SS4 version. Could you please describe the issue a bit more for...
View ArticleForum Post: RE: OpenPlant Modeler SS5-- Flange with PN100
Hello Miso, The PN100 rating is not included to a default ratings list in OPM. So, first of all you would need to include it into the RATING_VALUE_MAP class. Open the OpenPlant_3D schema in the Class...
View ArticleForum Post: RE: AUTO PLANT - WORK AREA REFERENCE FILES
Hello, It should work fine that way, strange. Maybe it's for some reason just do not save the settings? Is it the same for all files/work-areas or just with the one file? Can you also see if the dwg...
View ArticleForum Post: RE: Data Manager 'Filter Builder'
Hello Alain, Unfortunately, this functionality is hard coded and there is no way for you to redefine these queries. However, there is already a Defect # D-83179 filed for this issue and it will be...
View ArticleForum Post: RE: AUTO PLANT - WORK AREA REFERENCE FILES
Justin, I do not see the reference files. Are the reference files supposed to be automatically added when set-up the work area or do I add those manually?
View ArticleForum Post: RE: Data Manager 'Filter Builder'
Hello Justinas, This is what I suspected. Thank you for confirming. It will surely not be fixed in DataManager XM and probably not in the V8i version but hopefully in the next generation of...
View ArticleForum Post: RE: Open Plant Model Server reference out piping with VBA
Is there way to get just the piping on a particular system currently we have everything that is related to the system? It won’t allow me to right click on the pipeline group under system. I can...
View ArticleForum Post: RE: Secondary Pipe Supports in Bentley Autoplant Piping
Thanks for your Query. “Misc attachment” tool is available for adding additional material for support. Go to piping Misc. attachments. Add material description you will get that description in bill...
View ArticleForum Post: RE: Open Plant Model Server reference out piping with VBA
Im also interesting in knowing how one should do this... Had an idea that maybe I could create a local/global "Query" on all pipelines....unfortunatly when referencing out a complete query I didnt get...
View ArticleForum Post: RE: Open Plant Model Server reference out piping with VBA
Jojje, I had tried that as well and it would show all the pipe lines on the system but it would not reference them out as a group. What I did find interesting was that if you right click on the...
View ArticleForum Post: RE: Open Plant Model Server reference out piping with VBA
Sorry guys the pictures didn’t come through the first time I posted, I updated the last two posts with the pictures I had attached. -Mark From: Mrc1986...
View ArticleWiki Page: Add New Properties in tooltip
Applies To Product(s): AutoPLANT Modeler/ AutoPLANT V8i Version(s): 08.11.11.113 Environment: Windows 7 32 bit, Windows 7 64 bit Area: N/A Subarea: N/A Original Author:...
View ArticleWiki Page: Bentley AutoPLANT and Navisworks
Applies To Navisworks users who need to view AutoPLANT graphics Product(s): AutoPLANT Piping / Equipment / Modeler Version(s): 08.11.10.182 Environment: Windows 7 32 bit, Windows 7 64...
View Article