Forum Post: RE: AUTO PLNT - RENAMING FILES
Hello, You can rename the project drawing through Relationship manager. Refer below screen shot. If you like to know more about the relationship manager. Navigate to path C:\Program Files...
View ArticleForum Post: RE: AUTO PLNT - RENAMING FILES
Hello, You can rename the project drawing through Relationship manager. Refer below screen shot. If you like to know more about the relationship manager. Navigate to path C:\Program Files...
View ArticleForum Post: Export a PXF
Hello, I am using AutoPLANT Piping SS4. Please add the attached model (through relationship manager) to any Mixed Metric project. I am trying to export a PXF (choosing any component or the whole...
View ArticleWiki Page: Translate wrapped text from Autocad to Navigator
Applies To Product(s): Bentley Navigator Version(s): 08.11.08.43 Environment: N\A Area: General Subarea: N\A Original Author: Todd Cassell, Bentley Technical Support Group...
View ArticleWiki Page: How To set Component Dimension in OpenPlant Isometrics Manager
Applies To Product(s): Bentley OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: Original Author: Rahul...
View ArticleForum Post: RE: AUTO PLANT-PROJECT FILE ORGANIZATION
Hello CADTech, AutoPLANT stores specific files according to the type of the drawing. For rexample Pi[ping drawing will be stored in %Project root%.. Piping/ and same for P&ID and equipment in to...
View ArticleForum Post: Troubles with flattener
Hello. I have some trouble with flat my DWG files - lost piping lines. Screen before flat (source DWG, after purge, audit, bind xref) Screen after flat (flat file) What are the reasons?
View ArticleForum Post: RE: AutoPLANT V8i (SELECTseries 5) has been released!
Bentley people, end of Q2 has come and gone. where is AutoCAD 2013 or 2014 or 2015 support? AutoCAD 2013 support was talked about 1 year ago, then scrapped for 2014 support in Q1 then delayed to Q2....
View ArticleForum Post: OpenPlant Modeler SS5-- Flange with PN100
Hi, I want to construct a Flange with PN100 for the pipes DN100, DN150 and DN200.. i could not find the PN100 in the specifications !! could anybody tell me how i can add the PN100 to the Data Base ?...
View ArticleForum Post: Open Plant Model Server reference out piping with VBA
I don't know if this is in the correct spot or not so if it needs to be moved le me know. What I am trying to see if it is possible, is within open plant model server inside of Microstation you can...
View ArticleForum Post: AUTO PLANT - WORK AREA REFERENCE FILES
Hello, I am learning Auto Plant V8i and following the Bentley Learn server Plant Design Fundamentals. I am on the chapter covering Work Areas. I have set-up a work area and set the reference files...
View ArticleForum Post: RE: AUTO PLANT-PROJECT FILE ORGANIZATION
Dinesh, So the Regapp tells the database what the object type is and where to place it?
View ArticleForum Post: RE: Troubles with flattener
Hi Dmitry, I have experienced this as well. Are you using flattener with AutoCAD 2012? In the readme files it states that there are known issues and that flattening should be performed with AutoCAD...
View ArticleForum Post: RE: Export a PXF
I downloaded it and opened in sample Mixed Metric configuration, and it exported without any error. Try to open it in the sample project or config and see if it has the same error. If so, I would...
View ArticleForum Post: Secondary Pipe Supports in Bentley Autoplant Piping
Hi, Can anyone tell me how to show secondary strucutural supports in Bentley Autoplant Piping? Like we show 'U' bolts in 3D model and it is also appearing in bill of material list in isometric drawing.
View ArticleForum Post: RE: Troubles with flattener
Hi Yes, I use AutoCAD 2011. Microstation?.. May be in future... AT_HIDE command gives error Could not retrieve viewport boundary. Operation aborted. Error status = -5003 current CAD Error message =...
View ArticleForum Post: RE: Export a PXF
Please try to export it 3,4 times. The first time it works but second and third it is not for some reason. I tried what you suggested but still getting the same error in numerous stations. Regards Alex
View ArticleForum Post: RE: AutoPLANT V8i (SELECTseries 5) has been released!
Hello fross, AutoPLANT V8i (SELECTseries 6) has been released in the middle of June, which is supporting AutoCAD 2014. Please see the following link for more details:...
View Article