Forum Post: RE: AUTO PLANT-UNITS SETTING

Dinesh, I noticed a lot of my files are set to Architectural unit type and Inches for units. Ā I typically work in Decimal unit type/Feet and the scale pull-down I have set to unitless.Ā  I do not...

View Article


Forum Post: RE: AUTO PLANT-EQUIPMENT PLACEMENT

Dinesh, Ok, so if I want to change the name of a Location Point, it looks like I must delete the point and make a new point reflecting the new name?

View Article


Forum Post: RE: AUTO PLANT-WORK AREA

Dinesh, You are correct, when I make the reference path "full" instead of "relative", I get the complete path.

View Article

Forum Post: RE: AUTO PLANT-EQUIPMENT "BASE" POINT

Dinesh, Still not getting any change in elevation of my pump after changing the elevation of the location point. Ā Maybe my location point is not associated with the pump. Ā If I wanted to establish a...

View Article

Forum Post: RE: AUTO PLANT-EQUIPMENT COORDINATE

Dinesh, I used the foot mark but still no change in equipment location. Ā Is there a way to test if a location point is properly associated with an equipment?

View Article


Forum Post: RE: AUTO PLANT-EQUIPMENT LOCATION

Is the Master Node the base point for placing equipment?

View Article

Forum Post: RE: AUTO PLANT-EQUIPMENT LOCATION

The node is the insertion point of the Equipment.

View Article

Forum Post: RE: AUTO PLANT-EQUIPMENT LOCATION

How do I turn it on?

View Article


Forum Post: RE: AUTO PLANT-EQUIPMENT LOCATION

I am sorry If I have misunderstood your question. if you mean switching ON Master node from the Technote below:...

View Article


Forum Post: RE: AUTO PLANT-EQUIPMENT COORDINATE

Hello CADTech, Please try giving higher values to see if it changes. Also, try changing the co-ordinates as well. Co-ordinates and elevation could be checked using AutoCAD command ID for verification....

View Article

Forum Post: RE: AUTO PLANT-EQUIPMENT "BASE" POINT

If you mean switching ON Master node from the Technote below: communities.bentley.com/.../4271.how-to-hide-nodes-for-components-that-appear-out-in-space-tn.aspx The command for equipment is :...

View Article

Forum Post: RE: Troubles with flattener

I found a error - there was a problem in the main file

View Article

Forum Post: RE: Creating own elements

I made changes to all files, in the specification element is added. Create a drawing element, as it is written on the link above But when I set the item in the drawing, the ports coordinates are...

View Article


Forum Post: RE: Autoplant Valve Topworks Orientation in Isogen

Hello Ken, This is limitation of ISOGEN. Directional annotations for topworks that have primary orientations (North, South, East, West, Up, Down etc) are suppressed in generated isometric. As possible...

View Article

Forum Post: RE: AUTO PLANT-EQUIPMENT PLACEMENT

You are correct this is a limitation. There is no option to edit the name of the location points.

View Article


Forum Post: RE: AUTO PLANT-UNITS SETTING

Architectural Type is used with Imperial project however, changing it to decimal will not affect. But, it would matter if one file was set to inches and other file is set to feet.

View Article

Forum Post: RE: Open Plant Model Server reference out piping with VBA

Unit works great when referencing out objects. I believe you have our workspace already because you are working on an SR that was submitted for a different issue. The ticket number is 7000220168, if...

View Article


Forum Post: RE: Open Plant Model Server reference out piping with VBA

Hello Brian, Yes, I actually just saw that these are the same workspaces. I have used the original static queries for UNIT/SERVICE in Project\DataSet\ModelServer folder and created these for your...

View Article

Forum Post: RE: Open Plant Model Server reference out piping with VBA

Justinas, I placed these queries in the workspace and everything is referencing out now, thank you. So, if later down the road we add in a new model server node all I need to do is copy one of these...

View Article

Forum Post: RE: I-model export - Level state on/off

In Microstation 8 views can be defined differently. So if you change off some level in View 2 and create an Iā€“Model they are switch off in view2. However, settings are saved for the I-model, If you...

View Article