Well, setting pipeline as a root node might not be what you really need here. It would just basically show Pipeline as a node in the OPMS browser right under the ZEC_Corp project, like it's with Area, Sub-System, System. In your case here, from the screenshot, if you jut right-click on the STG System, reference it out you should get what you need. If anything is changed later on within that System (components added/removed/updated) once model will be refreshed the changes will be updated. If you would reference out components by a Pipeline, only the scope of that pipeline will be update, thus if you would create a new pipeline in the STG System, refresh command would not automatically update it, and user would need to manually reference that new pipeline to the model. So generally, using the higher level of relationships is a better idea. Regards, Justinas