Forum Post: Barcode
hi, i using autoplant v8i ss3 and I would like to add a barcode to my isometrics when i run them through isogen. I can add the field I want to the POS file to get it to come out in the right position...
View ArticleForum Post: RE: Microstation V8i and OpenPlant 3D Seed files: What is the...
Parijat, I believe there is not much differences between out of the box Microstation and OPM seed files. That is, you can use a Microstation 3D seed for your OpenPlant model creation. Of course, as we...
View ArticleForum Post: Upgrading a Project
Hello, Is there a document that specify the procedure of how to upgrade a project that was created in AutoPLANT 2004 version to AutoPLANT V8i (for example, SS4) version? Looking forward hearing from...
View ArticleForum Post: RE: Upgrading a Project
Hello Alex, This information is available in AutoPlant Read Me file, upgrading project section. Below is section from SS4 Read me: V8 2004 (v8.6) and XM (v8.9) Project Upgrades All pre-V8i legacy...
View ArticleForum Post: RE: Upgrading a Project
Also, here is the article regarding this on the wiki: communities.bentley.com/.../2473.aspx Regards, Justinas
View ArticleForum Post: RE: Valve Topworks
Hello Ken, One of the way is to edit ebs script and add additional parameter to the text box. As example I will use AT_TOPWORKS_HANDWHEEL class and try to go step by step to get a result as on a...
View ArticleForum Post: RE: Barcode
Hi kfitz, thanks for pointing us of the incorrect link in the wiki. The sample POS file mentioned in that article can be found here: communities.bentley.com/.../47891.aspx I've also updated the...
View ArticleWiki Page: Change The Color And Font For Text Placed By The Text Positon POS...
Applies To Product(s): AutoPLANT Version(s): 2004, XM, V8i Environment: N/A Area: N/A Subarea: N/A Original Author: Joey Bertone, Bentley Technical Support Group...
View ArticleForum Post: OpenPlant Modeler with managed workspace in multiproject datasource
Hi, I'm using OPM SS5 with PW SS4, where i have multi project datasource. Schemas are loaded from metric project (Bentley sample). Now I'm little uncertain that can I use mixed metric piping...
View ArticleForum Post: RE: Isogen MTO Overflow drawing not being supplemented with A suffix
Hello Ken, Just want to duplicate information that I have emailed you so it would available for every one: Option Switch 30 is responsible for Drawing Identifier that is putted in the drawing frame,...
View ArticleForum Post: RE: OPPID: functions in ECExpression
Good morning Justinas, Sorry it took me so long to answer but I have been busy on other projects. I have been looking at the wiki page and I have been trying but somewhere I must be doing something...
View ArticleWiki Page: How to add custom associated items as root nodes in the Item Browser
Applies To Product(s): Bentley OpenPlant Modeler Version(s): 08.11.09.383 Environment: N/A Area: Schema Subarea: Original Author: Justinas Lipnickas, Bentley Technical Support...
View ArticleForum Post: RE: OPPID: functions in ECExpression
Wim A. Can you give meteh following information: What property? Is this one of the Associated Items? (Area, Service, Unit System) I have composed a document with inforamtion on using System Strings in...
View ArticleForum Post: RE: OPPID: functions in ECExpression
Good afternoon Tony, This is about a new property "TAG_CODE" that I inserted in the "INSTRUMENT" class. The purpose of this property is to display the number of the instrument with the suffix at the...
View ArticleForum Post: RE: OpenPlant Modeler with managed workspace in multiproject...
Pekka, You do not need a new datasource. Just set up a new project using the correct units. If you are using managed workspaces, you would also want to create a new Project configuration block and...
View ArticleForum Post: OPPID SS4 - AT_PROJ.dbf
I have created a new project from a copy of another project, all seemed well until I recieved this message "Project ID '0003' not found in AT_PROJ.DBF. But when I open that file there is a record with...
View ArticleWiki Page: Adding “Existing” attribute to component preferences menu
Applies To Product(s): AutoPLANT Piping Version(s): N/A Environment: N/A Area: Settings/Attributes Subarea: Original Author: Artiom Jakubovic, Bentley Technical Support Group...
View ArticleWiki Page: Steps to get the Center of Gravity out of a piping model.
Applies To Product(s): AutoPLANT Piping Version(s): 08.11.08.151, 08.11.09.140 Environment: N/A Area: General Original Author: Dinesh Solanki, Bentley Technical Support Group...
View ArticleWiki Page: How Do I Allow Two Users To Access The Spec At The Same Time [TN]
Applies To Product(s): AutoPLANT Piping, Equipment, Isometrics Version(s): AutoPLANT V8i 08.11.05.36 Environment: N/A Area: N/A Subarea: N/A Original Author: Derek Cornell ,...