Wiki Page: Connection Lines in the center of Ball Valves
Hello all,When placing a ball valve with an actator or an instrument bubble where the connection line connects at the center of the circle (ball) on the valve cell the line will cross the outer edge of...
View ArticleForum Post: Re: Component preferences dialogue box does not display piping.
Hi Paul, this is probably way too late for you, but I've just discovered that the cause for us having the exact same issue is installing AutoCAD 2006 (32bit) either before or after having V8i...
View ArticleForum Post: Re: PASSWORD REQUIRED
Hello Alex,Try to remove a password from the project.mdb file by opening it in MS Access and following these steps...
View ArticleForum Post: Re: OPPID – How to get the PipeRun Insulation property to the...
Sanrise,INSULATION is not a "Double", its a String. INSULATION_THIKCNESS was a Double.If you set the INSULATION property on the Annotation class to a STRING then it should work as you have it defined...
View ArticleForum Post: Re: OpenPlant Modeler Administrator Training - Complaint
Hi cswnow,We are looking at Openplant at the moment and have to say that your comments are very concerning to us. We are similar in that we are only a small practice and would have thought that our...
View ArticleWiki Page: How to add a new Note and have it annotated on Page Connectors?
Applies To Page Connector Annotation Product(s):OpenPLANT P&ID Version(s):08.11.10.39 and greater Environment: N/A Area: Annotation Subarea: Notes Original Author:Bentley Technical Support...
View ArticleForum Post: Error : Field:[VNUM] value has length that does not fit in the...
Dear Bentley Team, I want to test some modification on seperate drawing file but on existing drawing, hence I copied the orginal autocad .dwg file to other location and rename it. Then while opening...
View ArticleForum Post: RE: Error : Field:[VNUM] value has length that does not fit in...
Hello Swapnil, Please try to increase field size of VNUM filed in VALVE table of Projdata in current project. Default size of this field is 10. I hope this information will help. Regards, Artiom...
View ArticleForum Post: RE: Installing SS5
Hello everybody, I'm trying to install the new version of AutoPLANT SS5, but installing the prerequisites, I get the following error Microsoft Hotfix kb982638 for .Net Framework 4 (error 1642) The...
View ArticleForum Post: RE: Installing SS5
I don't have any version of autoPLANT installed. is a new computer. Does anyone know something about it? I do not know what happens. Thanks, Roberto.
View ArticleForum Post: RE: Installing SS5
Hello Roberto, The error you are getting means that setup is not able to patch MS .NET framework 4.0, most likely because you do not have it installed, I would guess because you have .NET Framework...
View ArticleForum Post: RE: OpenPlant SS5 ERROR - index was outside the bounds of the array
Hello Rafael, Sorry for really delayed response to your query. I was wondering if this issue is still relevant for you? If yes, could you please provide some additional information for us to...
View ArticleForum Post: RE: Installing SS5
There are many changes in the installer of AutoPLANT SS5. The proper way is to uninstall any previous version of AP before installing AP SS5.
View ArticleForum Post: RE: Installing SS5
Hi JustinasL, I have installed "Microsoft .NET Framework 4.5.1". I trying to install the "Framework 4.0", but I can't. Windows 7 (x64) tell me "The same version or higher. NET Framework 4 is already...
View ArticleForum Post: RE: OpenPlant Modeller - Speed and Stability
Hi Scott Sorry for not responding sooner. We have had not luck with stabilising our systems (Dell laptops mostly). It is also very difficult to try and report these issues in a production environment,...
View ArticleForum Post: RE: Installing SS5
Hello everybody, Thanks for you solution JustinasL, Finally It was what you said, I needed the framework 4.0 and I had installed the version of Framework 4.5. I have had to uninstall the version...
View ArticleForum Post: RE: Transparency Issue
A single element’s transparency cannot be edited from the dialog. The whole level can set to a new color or transparency but not a single element. However the element can be added to an item set...
View ArticleForum Post: RE: OpenPlant Modeller - Speed and Stability
Hi Spyker, Scott, There are a couple of threads to look at in the MicroStation forums that might be helpful in terms of the graphics crashes that you are talking about. Please check these out:...
View ArticleForum Post: RE: Advanced selection
Hello Alex, Could you please try to register the dll and try again. Hope this helps! Regards Dinesh
View ArticleForum Post: RE: Component preferences dialogue box does not display piping.
the Link below communities.bentley.com/.../component-preferences-not-loading-properly-and-showing-corrupt-display.aspx could help as well.
View Article