Forum Post: RE: Insulation
Hello Alex, Have you ensured "Show Insulation" is ON on the machine affected ine drawing preferences dialog
View ArticleForum Post: RE: Advanced selection
IN order to follow up on this case. During live meeting we were not able to reproduce this issue. The possible solution remains accurate: As a workaround, please download projectservices.dll and copy...
View ArticleForum Post: RE: OpenPlant Modeller - Speed and Stability
Hi Rob Thanks for your inputs. I will get the tech guys to look at the display drivers. We are running OpenPlant PowerPID 08.11.1.202 How do we get to hear about priority builds? Thanks a stack Spyker
View ArticleForum Post: Root Position
Hello, I am using AutoPLANT SS4 on AutoCAD 2012. Please see the attached file. Is there a way to change a root position in the list? for example, I want the root C:\bentley-test to be last in the...
View ArticleForum Post: Equipment Annotation
Hello, I am using AutoPLANT Equipment SS4 on AutoCAD 2012. Please see the attached file. Is there a way to control the size of the Tag annotation (like there is in AutoPLANT Piping annotations)?...
View ArticleForum Post: RE: Installing SS5
The Prerequisites cannot find Microsoft .NET 4.0 to install Hotfix kb982638. The Hotfix will only install to .NET 4.0 and if another version or a newer version such as .NET 4.5 the hotfix will not...
View ArticleForum Post: RE: Root Position
Hello Alex, It seem it is not possible to change roots ordering. I could not find way to disable Ascending Ordering and use customized one. Regards, Artiom
View ArticleForum Post: RE: Equipment Annotation
Hello Alex, Below is information from Equipment Help file related to annotations: The size of the annotation is scaled using the values of the following setvars DIMTXT – Text size DIMSCALE – Scale of...
View ArticleForum Post: Specs in external databases
Windows 7 Enterprise AutoCAD 2012 x64 AutoPLANT V8i SS4 x64 Hi Everyone, I am experimenting with moving specs from MDB to storing them in a central SQL db instead. So far so good, with only one minor...
View ArticleForum Post: RE: Database Error in Crystal Reports (Generating BOM)
Good day. This is snapshot of error about enough memory. Seems to me It's happened not only in big drawings.
View ArticleForum Post: RE: Database Error in Crystal Reports (Generating BOM)
Maybe problem is version of Crystal Reports. I have Autoplant ss1. What version CR should i have?
View ArticleForum Post: AutoPLANT Piping file - units
Hello, I'm using AutoPLANT SS4 on AutoCAD 2012. When I open a new piping file or an existing file (and save it later), I see (in AutoCAD command - units) that the precision is 0. How can make the...
View ArticleForum Post: Master Spec Folder
Hello, I'm using AutoPLANT SS4 on AutoCAD 2012. Is there a way to define a new Master Spec Folder for each new project that I open? right now the default path for each new project is...
View ArticleForum Post: RE: Master Spec Folder
Hi Alex, Instead of using the "New Project" to create our projects, we typically create a configuration that contains the settings we need then drag that configuration over a project root to copy all...
View ArticleForum Post: RE: AutoPLANT Piping file - units
Hi Alex, If you are referring to units precision, this is stored in the Units.ini file found in two places In the installation at C:\Program Files (x86)\Bentley\Plant V8i\Config And in the project at...
View ArticleForum Post: RE: document id
Do you get this error opening a drawing? Try the following: 1. Copy the drawing to a temp folder. 2. Using Relationship Manager, delete the drawing from the project. 3. Using Relationship Manager,...
View Article