Forum Post: RE: Intelligent Line Manager / OpenPlant SS5
Hello Miso, And you are placing an Elbow or a Pipe_Bend component here? Regards, Justinas
View ArticleForum Post: RE: Intelligent Line Manager / OpenPlant SS5
Hi Justinas, thanks for replay, actually i tried both Standard Elbow AND a Pipe Bend components, even the other function (ask for corner type) but the same result always! Regards Miso
View ArticleForum Post: Bentley Instrument and Wiring - Create Multiple Cable and Terminal
I've used Instrument and Wiring for a few projects. So far, my experience is good using this software. I've also took 1 week course on Bentley I & W. Here what we learned during course : Design...
View ArticleForum Post: RE: Pipe bends definition in PSDS
I sort of chased back some of the component definition for bends; well at least enough to realize that they come delivered with a "user defined" option for the bend radius. I do have another question...
View ArticleWiki Page: Setting File Type (DGN or DWG) and Paper Setting
File / Paper Settings File Format The file format can be toggled between DGN and DWG on the Isometric Management tab of the Isometrics Configuration tool. Open the Isometrics Configuration tool...
View ArticleWiki Page: Modifying Text and Annotation Settings
Text and Annotations Text nodes are placed in the seed file as placeholders for attributes and reports on the drawing. The text nodes also set the properties for the text, such as font, size and...
View ArticleWiki Page: Modifying Dimension Styles
Dimensioning Dimension Styles Dimension definitions (styles) are configured in the isometric seed file. Although...
View ArticleWiki Page: Modifying the Iso Content
Iso Content North Direction The north direction and label formats can be set for each Isometric Style. Use the steps below to set the north direction. Open the Isometrics Configuration tool From...
View ArticleWiki Page: Configuring the BOM and Reports
BOM / Report Configuration The material report on the drawing is controlled with the report definition file (report.def). This definition file provides a very flexible way of specifying the material...
View ArticleWiki Page: Modifying the Welding Information
Welding Weld Summary Report A weld summary report can be created by adding the CT_WELD component type to the INCLUDE keyword in the report as follows: INCLUDE = IE_TYPE=CT_WELD COLUMN = 6:C:WELDID...
View ArticleWiki Page: Modifying Color, Line Style and Line Weight of Piping and Components
Symbology The Component Placement section in the Configuration Manager controls the color, line style and line weight of piping and components in the drawing. Open Bentley Project Administrator...
View ArticleForum Post: AutoPlant SS5 Installation problem
Hello! I have problem with AutoPLANT SS5 installation. I installed AutoCAD 2012 SP2, ProjectWise Administrator, ProjectWise Explorer, Prerequisites and Common Tools for AutoPLANT Applications v8i x64,...
View ArticleWiki Page: Modifying Symbols
Symbols Isometric symbols used on Isometric Drawings are stored in cell libraries. Based on company requirements an Administrator will need to modify existing symbols or to create completely new...
View ArticleForum Post: AutoPLANT run failed
Hello! During running AutoPlant SS5 (when i Opening document from ProjectWise Explorer) show follow errors: During try initialize Piping and etc. I use AutoCAD 2012 x64 SP2, ProjectWise 08.11.11.574,...
View ArticleForum Post: RE: AutoPLANT run failed
Unfortunately, your screenshots are not visible.. Could you please try reattach them?
View ArticleForum Post: RE: AutoPlant SS5 Installation problem
Same as in the other post, please try reattaching the error snapshot. Justinas
View ArticleForum Post: ProjectWise Class Editor (08.11.11.566)
Hi, I am "hijacking" the functionality in the ProjectWise Class Editor, using custom database views to create new classes and forming hierarchical searches in the Components tree. I am relating...
View ArticleForum Post: A fatal runtime error.
When I start PSDS, an error message just showed up as follows: Microsoft Visual C++ Runtime Library / Runtime Error! / Program : C:\Program Files\Bentley\MicroStation\ustation.exe / abnormal program...
View ArticleWiki Page: AutoPLANT Modeler [FAQ]
AutoPLANT project versions and Bentley® OpenPlant Isometrics Manager How do I purchase AutoPLANT applications? Is OpenPlant Isometrics Manager available through AutoPLANT® Modeler SS5 installer ? What...
View Article