Forum Post: RE: Error "ATDB0805 : Unable to get the Document ID from the...
Hello Swapnil, Are there any xref's in the AutoPLANT model? Make sure the xref's are present in your AutoPLANT project. Please let us know if this helps. Regards Dinesh Solanki
View ArticleForum Post: RE: Error "ATDB0805 : Unable to get the Document ID from the...
Hi, Yes, all xref's are present, still we are faced the issue. Further, by adding the drawing manually to project , through the relationship manager, we solved this issue.
View ArticleForum Post: RE: Error "ATDB0805 : Unable to get the Document ID from the...
Hello Swapnil, Yes, the models should be present in AutoPLANT model. You can use relationship manager to do this operation. Regards Dinesh
View ArticleForum Post: RE: OPPID Service Error : Deletion
Hello Krishna, Unfortunately I haven't found any possible way how to delete all services at once. Due to the fact that all Services where created/converted within the drawing, Bnetley OpenPlant PID Vi8...
View ArticleForum Post: RE: AutoPLANT administrators - HOW TO
Hi, I'm about to move Autoplant SS4 SQL databases and files to new SQL server. Is there any step by step instruction how to proceed? New share will ramain with same name and drive letter assigned.
View ArticleForum Post: RE: AutoPLANT administrators - HOW TO
Hello Tomasz, Please see steps below to accomplish move to new server. How to change an AutoPLANT Piping project database to a new SQL Server Regards Dinesh Solanki
View ArticleWiki Page: Copy Models Option Does Not Copy files to Orthographics Manager...
Applies To Product(s): OpenPlant Orthographics Manager Version(s): 08.11.09.564 Environment: Windows 7 64 bit Area: ProjectWise Subarea: Original Author: Dinesh Solanki, Bentley Technical Support Group...
View ArticleWiki Page: How to Show Leader Line\ Dimension Line
Applies To Product(s): OpenPlant Orthographics Manager Version(s): 08.11.09.564 Environment: Windows 7 (64 bit) Area: Settings Subarea: Original Author: Dinesh Solanki, Bentley Technical Support Group...
View ArticleWiki Page: How to control Insulation Representation in OpenPlant...
Applies To Product(s): OpenPlant Orthographics Manager Version(s): 08.11.09.564 Environment: Windows 7 (64 bit) Area: Settings Subarea: Original Author: Dinesh Solanki, Bentley Technical Support Group...
View ArticleWiki Page: How to Modify Gap between Line Number and Elevation
Applies To Product(s): OpenPlant Orthographics Manager Version(s): 08.11.09.564 Environment: Windows 7 (64 bit) Area: Settings Subarea: Original Author: Dinesh Solanki, Bentley Technical Support Group...
View ArticleWiki Page: How to not show Welds in Orthographic Output
Introduction Sometimes it is not required to show welds in Othographic output. Orthographic hidden line mode can be used to attain this requirement. Steps to Accomplish Change Hidden line mode to...
View ArticleWiki Page: How to Differentiate Between Multiple Records for Topworks in Spec.
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Component Subarea: Original Author: Harpreet Singh, Bentley Technical Support Group Scenario: When...
View ArticleWiki Page: How to Place Multiple Welds in Straight Piece of Pipe at Equal...
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7/8 (64 bit) Area: Component Subarea: Original Author: Harpreet Singh, Bentley Technical Support Group Background...
View ArticleWiki Page: Component - OpenPlant Modeler
Component- OpenPlant Modeler See Index: Cannot Update Calculated Bolt Lengths in Description Field Delete/Replace the Flange Assembly in Open Plant Modeler Forcing OPM to Redraw Pipelines According To...
View ArticleWiki Page: To Modify Pipeline Tag Name in OpenPlant Modeler
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.564 Environment: Windows 7 (64 bit) Area: Properties Subarea: - Original Author: Rahul Kumar, Bentley Technical Support Group Overview To...
View ArticleComment on Map New AutoPLANT Relationship in OPIM Schema
Please note the following corrections: - Under "Define Custom Attribute", in step 1, you are creating a mapping to the AutoPLANT Relationship Name, not to the actual database table name. References to...
View ArticleForum Post: OPIM Valve Operator Symbol in Isometric
HI , I am trying to assign a new symbol to user defined operator.. I have query as per attached screen shot , Regards, Vivek
View ArticleForum Post: RE: OPIM Valve Operator Symbol in Isometric
Hello Guys, It's different than others but style config folder have operator.tbl files for defining this relation...
View ArticleForum Post: RE: Spec gen
Hello Alexander, Thank you for writing your query. May I know which product you are using with Spec Gen? Also please mention the version and other information like what steps your are trying to....
View Article