Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Component Subarea: Original Author: Harpreet Singh, Bentley Technical Support Group Scenario: When there are multiple records of TopWorks (say HAND_WHEEL) in the spec then while placement of valves (Gate Valve & Globe Valve) software does not differentiate between the records and places the HAND_WHEEL with same dimension on both the valves. Changes to be made in Spec Using OP-SpecGen: Open OP Specification Generator. Load the Spec in Spec Gen & go to Gate Valve section. Add a constraint ‘TAG’ from the second icon in this section as shown below. 4. Now click the last icon on this section i.e. Define Section Descriptions as shown below: 5. In this dialog box click icon with + sign i.e. ‘Add Column’ – TAG. 6. Right click on VALUE field and type [GATE] in this highlighted area as shown below and click green check button. 7. Similarly repeat steps 3 to 6 and add value [GLOBE] for TAG property in ‘Globe Section’. Please see below: 8. Now go to TOPWORKS section and add TAG constraint. 9. Add the same values for gate valve and globe valve as shown below: 10. Save the Spec. Changes to be made in Schema: Open OpenPlant_CustomAttributes.08.11 schema in class editor from below given path. C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\OPModeler\schemas. Now open OpenPlant_3D.01.04 schema in class editor from project schemas and supplement it with OpenPlant_3D_Supplemental_Modeling.01.04. Expand the Classes node and go to Plant Base Object\Named Item\Device\Valve Operating Device\Manual Valve Operating Device\Hand Wheel. Right click on HAND_WHEEL class and click Custom AttributesàADD/Remove. 5. Add OpenPlant_Physical_AdditionalDBQuery custom attribute in OpenPlant_3D_Supplemental_Modeling location and click OK. Please see below picture for your reference: 6. Right click on FieldName and click “Add Element” in context menu. 7. Type “TAG” in the FieldName and SAVE the schema. 8. Open OPM and verify the results.
↧