Forum Post: RE: OPIM - Linetype for continued/existing components

Hello Maggie, Also please note, the upcoming AutoPLANT version will support OPIM 08.11.09.5XX. Regards | Rahul Kumar

View Article


Wiki Page: Settings/Attributes- OpenPlant Isometrics Manager

Settings/Attributes - OpenPlant Isometrics Manager Settings/Attributes - OpenPlant Isometrics Manager To Discuss various settings desired to output Isometric drawings. See Index: Add New Valve Topworks...

View Article


Forum Post: RE: ATDB0718: Relationship Manager Error Code Reported -2147467259

Hello Mr. Pearson, Could you please make back up of your project as well as database and try below suggestion 1. Navigate to the project path. 2. Open RELATIONSHIPINSTANCE table in project database. 3....

View Article

Forum Post: RE: OPIM - Linetype for continued/existing components

Hi Rahul, Do you know when the new AutoPLANT will be released? Thanks, Maggie

View Article

Forum Post: RE: OPIM - Component Coordinations output control

I have tried but it did not seem to work. It remains as what it was on my my test pipeline

View Article


Forum Post: RE: OPIM - Linetype for continued/existing components

The overides.txt will work with OPIM 08.11.09.470 but it is not an official feature of that version so there may be issues running overrides.txt with that version.

View Article

Forum Post: RE: OPIM - Linetype for continued/existing components

I have tried following rule, it did not work. So I substituted COMP_STATE with STATE, but change. And then I tried DSTATE and DESIGN_STATE, all components except existing components become dotted, this...

View Article

Forum Post: RE: OPIM - Linetype for continued/existing components

Open the L00 log file for the model and check the variable name and its value. The Override rule uses the values in the L00 file and they may be different then the values from autoplant or openplant.

View Article


Wiki Page: How to: User Overrides for Isometric components

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: - Original Author: Joey Bertone, Bentley Technical Support...

View Article


Forum Post: RE: OPIM - Linetype for continued/existing components

in the log file, it has IE_EXISTING and COMP_STATE. And I tried both IE_EXISTING=1 and COMP_STATE=FOR_DEMOLITION but with no luck

View Article

Forum Post: ATDB0719: Relationship Manager error code report -2147217887

Trying to place a component in a AutoPLANT Piping Model. ATDB0719: Relationship Manager error code report -2147217887 Microsfot JET Database Engine: Could not update; currently locked.

View Article

Forum Post: RE: ATDB0719: Relationship Manager error code report -2147217887

Hello Courtenay, Is it a new project? Make sure in component preferences line number, Area, Service, Unit have some values. Also, please provide more details. Regards Dinesh

View Article

Forum Post: I need help creatin an angled pressure relief valve (inlet DN25...

I need help creating an angled pressure relief valve (inlet DN25 CL300 - outlet DN50 CL150) I can get it to show and connect at the DN25 end but not the DN50 end any help would be apreciated. I have...

View Article


Forum Post: RE: I need help creatin an angled pressure relief valve (inlet...

Hi, Which product you are using? Regards, Harpreet

View Article

Forum Post: RE: I need help creatin an angled pressure relief valve (inlet...

Yes that was silly of me , AutoPLANT SS4

View Article


Wiki Page: Schema Changes Between OpenPlant Modeler Version 08.11.09.404 and...

Applies To Product(s): OpenPlant Modeler, OpenPlant Isometrics Manager, OpenPlant ModelServer Version(s): 08.11.09.440 Environment: N/A Area: Schema Subarea: Original Author: Rahul Kumar, Bentley...

View Article

Forum Post: RE: OPIM - Tag/Text, Part ID and Coordination

Hello Maggie, We could not reproduce the issue at our end with AutoPLANT 08.11.12.111 and OPIM 08.11.09.470. Could you let us know if there are other steps to reproduce the issue. Regards Dinesh

View Article


Wiki Page: Import/Export- OpenPlant Modeler

Import/Export We will discuss issues related to Import/Export in this section. See Index: How to Import/Export STP files in OpenPlant Modeler Error: 'Unable to open seed file:seed.dwg' while exporting...

View Article

Forum Post: RE: OPIM - Tag/Text, Part ID and Coordination

It is an existing blind flange/existing plug attached with an instrument bubble

View Article

Wiki Page: Error: 'Unable to open seed file:seed.dwg' while exporting model...

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 (64 bit) Area: Import/Export Subarea: Original Author: Harpreet Singh, Bentley Technical Support Group...