Wiki Page: How To Set Reducer Size Annotation in BOM Report
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.404 Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley Technical Support...
View ArticleWiki Page: How to Import/Export STP files in OpenPlant Modeler
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 (64 bit) Area: Import/Export Subarea: Original Author: Harpreet Singh, Bentley Technical Support Group...
View ArticleWiki Page: Import/Export- OpenPlant Modeler
Import/Export We will discuss issues related to Import/Export in this section. See Index: How to Import/Export STP files in OpenPlant Modeler See Also Product TechNotes and FAQs OpenPlant Modeler...
View ArticleForum Post: ATDB0718: Relationship Manager Error Code Reported -2147467259
I have an AutoPLANT Equipment model (2012) and when i open the model i get this error: ATDB0718: Relationship Manager error code reported -2147467259 At_ArxObjRel.arx: at at_ArxObjRel_addRelInst: The...
View ArticleForum Post: RE: OpenPlantIsomatric Manager - Cannot list more than 15...
Thanks for the reply, Dinesh. Do you know if prerequest update 08.11.12.114 have this problem solved? Thanks, Maggie
View ArticleForum Post: RE: OPIM - Component selection and connection criteria
Thanks Dinesh. The update solve the component selection while running OPIM, but connection criteria "Use Project Settings" check box is still disable.
View ArticleForum Post: OPIM - Linetype for continued/existing components
The current OPIM use same linetype and same linetype scale for both existing pipe and existing components. If linetype scale is big, existing components do not form a shape in print out; if the...
View ArticleForum Post: OPIM - Component Coordinations output control
Is it a way to control coordination output on components? For some pipelines, it output too many and make ISO image too crowdy. Please see attached image.My guess it most likely occuring on existing...
View ArticleForum Post: OPIM - Tag/Text, Part ID and Coordination
Can Tag/Text, Part ID and coordination output to have seperated leaders? Please see attached image. In this image, Tag, PartID and coordination shared with one leader, and making information block too...
View ArticleForum Post: AP Project Information Differs
Hi, I have created a New Project for OPPID as per given Procedure, But when i opened a new created drawing i get following dialogue box error (See Image 1) I dont know how The drawing gets connected to...
View ArticleForum Post: RE: AP Project Information Differs
Hi Krishna, Are you working in Projectwise environment? Also try the following steps in the drawing which is trying to connect to other project. 1. Open the drawing. 2. Go to Utilities>Key-in. Type...
View ArticleForum Post: RE: OpenPlantIsomatric Manager - Cannot list more than 15...
No, you should install OPIM 08.11.09.470 to correct the issue.
View ArticleForum Post: RE: AP Project Information Differs
Hi Harpreet, Yes I am working in Projectwise environment. Yes i am aware of that command and we are using it also, specially when we are converting from APPID to OPPID or when we want to use Existing...
View ArticleForum Post: RE: AP Project Information Differs
Can you provide your email ID? I will contact you to setup a meeting. Regards, Harpreet
View ArticleForum Post: RE: AP Project Information Differs
Hi Harpreet, My Company Email ID is "Krishna.natkar@ausenco.com" Regards, Krishna Natkar.
View ArticleForum Post: RE: OPIM - Component Coordinations output control
Hello Maggie, One Possible way to remove extra co-ordinates by checking OFF the 'Coordinate Labels at All Extremities' option. This Will show the Co-ordinates only at the End point and disable others....
View ArticleForum Post: RE: AP Project Information Differs
Hi Krishna, As per our discussion during remote session, the issue we figured out is that the seed file might have been copied from other project and when a new file is created from this seed file it...
View ArticleForum Post: RE: OPIM - Linetype for continued/existing components
Hello Maggie, This is possible with latest 08.11.09.564 version only. See example#2 discussed in wiki link refer below: Hope this is a helpful information. Regards | Rahul Kumar
View ArticleForum Post: RE: OPIM - Component selection and connection criteria
Hello Maggie, OPIM does not offer project setting option. Regards Dinesh
View ArticleWiki Page: How to Suppress Branch Dimensions by Size in OPIM
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.566 & Above Environment: Windows 7 (64 bit) Area: Settings/Attributes Subarea: - Original Author: Rahul Kumar, Bentley...
View Article