Wiki Page: How to Use an Intermediate File (L00) to Review Isometrics Drawings
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.564 Environment: Windows 7 64 bit & Others Area: Processing Subarea: Original Author: Rahul Kumar, Bentley Technical Support...
View ArticleWiki Page: How to Change Miscellaneous Attachment Annotation Container
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.404 & above Environment: Windows 7 32/ 64 bit Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley...
View ArticleWiki Page: How Do I Upgrade Projects From AutoPLANT XM To V8i [TN]
Applies To Product(s): AutoPLANT Piping Version(s): XM, V8i Environment: N/A Area: N/A Subarea: N/A Original Author: Bentley Technical Support Group Overview When AutoPLANT is upgraded from XM to V8i...
View ArticleForum Post: RE: File Error, Missing Application: At_Reboids
Hello Dave, I believe it should be possible to download object enabler for any registered user. In case this is not possible. Please submit a service request under Website Assistance. Regards, Artiom
View ArticleForum Post: How to add Nozzle size on Isometric?
When we extract the isometric which is connected to Equipment Nozzle, normally it shows the Nozzle Tag, Nozzle Rating and Nozzle facing in continuation. But I want to add Nozzle size as well in...
View ArticleForum Post: RE: How to add Nozzle size on Isometric?
Hello Sandip, Are you trying this with OpenPlant Isometrics Manager or an ISOGEN? we have a similar content available in context with OpenPlant Isometrics Manager. Please have a look below: Regards,...
View ArticleForum Post: RE: How to add Nozzle size on Isometric?
Hi Rahul As mentioned in my previous post, we are using AutoPLANT SS4 which uses isogen to extract the isometric. If I am not wrong OpenPlant Isometric Manager is introduced in AUtoPLANT SS5. Please...
View ArticleForum Post: RE: How to add Nozzle size on Isometric?
Hello Sandip, Could you please try following steps: 1. Open C:\Program Files (x86)\Bentley\Plant V8i\Modules\Base\xchg\pcf\eqpnozz.ebs. 2. Go to Line 85 and insert the code below under the code for `//...
View ArticleForum Post: RE: How to add Nozzle size on Isometric?
Hi Sandip, In order to get nominal nozzle size in continuation reference message the following ebs file should be edited: C:\Program Files (x86)\Bentley\Plant V8i\Modules\Base\xchg\pcf\eqpnozz.ebs As...
View ArticleForum Post: RE: How to add Nozzle size on Isometric?
Thnaks Artiom It works. Can we make that eqpnozz.ebs file project specific or I have to copy it on every users machine? Thanks and Regards Sandip
View ArticleForum Post: RE: How to add Nozzle size on Isometric?
Thanks Abhijit It works. Can we make that eqpnozz.ebs file project specific or I have to copy it on every users machine? Thanks and Regards Sandip
View ArticleForum Post: RE: How to add Nozzle size on Isometric?
Sandip, put the file to PROJECT_ROOT\Config\Modules\Base\xchg\pcf\eqpnozz.ebs Regards, Artiom
View ArticleForum Post: RE: OPIM & ProjectWise Title Block Syncing
Rahul, So I followed the steps in the tutorial stated above, but what I am trying to do is get the attributes into ProjectWise from an AutoPLANT OPIM session. What steps (could be basic outline) need...
View ArticleForum Post: RE: OPIM & ProjectWise Title Block Syncing
Hello Andrew, We are in discussion with development team. Will soon update you on this. Key-in seems to be a bottle neck part on this. I have to check it. Regards, Rahul Kumar
View ArticleForum Post: Required Bentley Software
Can someone expert in plant design please let me know what are the software available in Bentley to address the following needs, Pulsation and vibration analysis Gas dispersion analysis Pipe stress...
View ArticleForum Post: RE: Required Bentley Software
Hello For Pipe Stress Analysis and Pulsation and vibration analysis Bentley has "AutoPIPE" Software. Bentley AutoPIPE V8i is the most productive design and analysis program for calculating piping code...
View ArticleForum Post: Create your own primary or supplemental OpenPlant Schemas?
Hello, I'm new on Bentley Communities. I have been using OpenPlant for a while and I have been adding some derived classes and attributes to the Bentley delivered schemas. In your experience what would...
View ArticleForum Post: RE: OPPID RSS5 - Borders and Tags
Tony, Our title block tag values are managed by ProjectWise so does the information go the other direction? Changes to the border tag values then changes the PID_DOCUMENT values. thanks
View ArticleForum Post: RE: Required Bentley Software
For i) Pulsation and vibration Analysis ii) Pipe stress Analysis We have to use AutoPIPE basic or advanced?
View ArticleWiki Page: How to Accumulate Weight Information and Round Up Quantity in Bill...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.470 Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: Original Author: Dinesh Solanki, Bentley...
View Article