Wiki Page: How to Accumulate Weight Information and Round Up Quantity in Bill of Material

$
0
0
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.470 Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: Original Author: Dinesh Solanki, Bentley Technical Support Group Background There could be requirement to get weight accumulated for the components and round up quantity in bill of material. Below are some simple steps to accomplish this necessity. This has been shown in context with AutoPLANT Modeler and OpenPlant Isometrics Manager. Steps to Accomplish Accumulating Weight Information: 1. Change the report.def like below image. 2. Create Iso using OPIM using the correct style where changes has been done you will notice weight has been accumulated. Round Up Quantity in Bill of Material Open Style.cfg and change the variable to IE_FMT_LENGTH_ACCURACY= 1 Previous Result: Result after Changes to Style.cfg: See Also http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/12642.configuring-the-bom-and-reports Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!