Forum Post: ASSEMBLY MANAGER
IM TRYING TO MAKE AN ASSEMBLY OF AND RO WITH A PDI AND 2 GATE VALVES. IM NOT HAVING ANY PROBLEM CREATING THE ASSEMBLY, ITS JUST THAT I DONT QUITE GET HOW YOU ARE SUPPOSED TO UTILIZE "BREAK OUT LINES"...
View ArticleForum Post: Re: OPPID SS5 - Entering engineering data other than element...
Mark,Is your Project PCF file pointing to the proper project root directory and project ID?The line the PCF should look something like this:From the default OPPowerPID_Imperial.pcf file:# AutoPlantDB...
View ArticleWiki Page: OPPID - How to Copy Specialty Item and Tie In Points to the ISO...
Applies To Product(s):OpenPLANT PowerPID Version(s):08.11.10.38 and greater Environment: N/A Area: New Components Subarea: Original Author:Bentley Technical Support Group How to copy...
View ArticleWiki Page: Creating Custom Tie-In Component from a User Defined Cell
Hello all,Attached is a How To document that defines the steps to create a series of custom Tie-In cells/classes that will behave exactly like the parametrically generated Tie-In component that is in...
View ArticleForum Post: Changing Line length
How do I change the pipe line length after I have modeled it in PlantSpace?
View ArticleForum Post: View Datasheet number in all AP P&ID Data Manager Tables
Hi,I'm trying to figure how to put the datasheet number in all the Data Manager database views (Equipment Lists, etc.), because at the moment it appears only in the instruments table.Thanks in advanceGG
View ArticleForum Post: Re: Component preferences will not load (Series 4 with AutoCAD2012)
Hi Swapnil,Here are some brief answers to your questions:1. The greatest limitation of using an Access database is that they are not able to effectively handle multiple concurrent users. This makes...
View ArticleForum Post: WHAT DO YOU HAVE TO DO TO EDIT USER EQUIPMENT?
IS THIS POSSIBLE, OR DO YOU HAVE TO ERASE AND RE-CREATE?
View ArticleForum Post: Re: OPPID SS5: How to get service from pipe run into instrument?
Tony,Yes, now it's working. Instrument and valve can get the right service-property automatically.- Sanna
View ArticleForum Post: Re: OPPID Plant Areas, Systems and Services
Jeff,The PLANT_AREA, SERVICE, SYSTEM and UNIT all write to separate tables in the plant project database. The tables are named OPPID_AREA, OPPID_SERVICE, OPPID_SYSTEM and OPPID_UNIT. These tables will...
View ArticleForum Post: Re: Nominal Size with decimal places on isometric Drawing
Option Switch 41, doesn't work with this
View ArticleForum Post: Re: ID BUBBLE RADIUS
Hello, Unfortunately, It seems to me there is no way to regenerate ID Bubbles so they would meet current ID Bubble Radius.Regards, Artiom
View ArticleForum Post: Re: Unable to create new project in Win7-64bit having Bentley...
Hello Swapnil M Gholap, I have seen similar message when user did not have enough permissions to modify files in project creation root. Could you please check if the user has sufficient permissions? As...
View ArticleForum Post: PlantSpace - Configuration
We have moved forward from PlantSpace Equipment and Piping to OpenPlant but still have one project using PlantSpace Raceway. We are continually getting error messages that on 15 min are left in trial...
View ArticleForum Post: OPPID : Strange error messages when converting pipes from...
Good afternoon,When converting PID's from plantspace PID XM to PowerPID I get this message:After conversion, some of the pipes from wich the ID's match with the ones in the errors are not...
View ArticleForum Post: Re: Data selection from external database with filter
Thanks a stack for the feedback...Spyker
View ArticleForum Post: Re: OPPID SS5 - Creating and adding Company or Client Borders
You could just exchange the existing graphics in the delivered cellib.To gain level administering OPPID requires some knowledge that goes beyond the forum. The quickest and comprehensive approach would...
View ArticleForum Post: Re: Unable to create new project in Win7-64bit having Bentley...
Thank you for your reply.I am not sure what could be cause of this issue, but still believe it has some relation to user permissions. Could you please check if user have full control permissions on...
View ArticleForum Post: Re: Insulation of equipment in different color/ layer.
Hello Swapnil, As equipment insulation is placed on same layer it looks like this functionality is not provided. Never the less, i would recommend to contact Bentley Professional Service specialists....
View ArticleForum Post: Re: Error coming "PIP_0701 : Invalid size for demo version" while...
It is very rarely I have met licencing issues with AutoPlant. So not sure what could be wrong. Have you tried to run through licence activation under user account? Go to Licence Management Tool >...
View Article