Wiki Page: No loading of the tool pallets needed in AutoPLANT Piping.
Applies To Product(s): AutoPLANT Piping Version(s): 08.11.12.111 Environment: Windows Vista 64 bit Area: Open/Save Subarea: N\A Original Author: Berrie Geboers, Bentley Technical Support Group Problem...
View ArticleWiki Page: OpenPlant Product Group Compatibility
The attached PDF document has OpenPlant Releases Compatibility information towards different operating systems and database types. (Please visit the site to view this file) This PDF file has...
View ArticleForum Post: RE: Manully set to name isometric drawings for OPIM
Thanks Joe and Xiongfei for the testing so far. Yes I got the user concern here. Also after few test on changing expressions in schema, program does not allow to change the name of output DGN file name...
View ArticleWiki Page: Modifying Symbols
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: - Original Author: Keith Couvillion, Bentley Technical...
View ArticleWiki Page: Modifying Weld Symbol Size
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley Technical Support...
View ArticleWiki Page: Modify Label Tool Does Not Work When Removing Boundary/Box around...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.404 Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley Technical Support...
View ArticleWiki Page: Modifying Rectangular enclosure/Boundary in Open Plant Isometric...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.404 Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: Original Author: Rahul Kumar, Bentley Technical Support...
View ArticleWiki Page: How to Show Corner type Elbows on Isometrics
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.404 & above Environment: Windows 7 64 bit & Others Area: Settings/Attributes Subarea: Original Author: Rahul Kumar,...
View ArticleForum Post: Instrument support tee stand, graphics or units problem for...
whenever I insert instrument support tee stand in Metric or Mix Metric project graphical representation of component is very small please refer attach image, else in Imperial it work fine. Its look...
View ArticleForum Post: RE: OPM custom component as a 3d Sign
If anybody is interested I found a keyin to create the component. "mechaddin makeinstance some_suitable_component". A component created in this way does not get any relationships thou(for example...
View ArticleForum Post: RE: autoplant isogen item code
This is a limitation of ISOGEN. It uses ITEM-CODE to link the top (drawing) section of the PCF to the bottom (BOM) section. If there is a difference, it will append the _1 to the ITEM-CODE. Try...
View ArticleWiki Page: How To Add New Fields In The ISOGEN BOM Such As Rating Or Schedule...
Applies To Product(s): AutoPLANT Isogen Version(s): All Environment: N/A Area: N/A Subarea: N/A Original Author: Bentley Technical Support Group To Add New Fields to the Isogen BOM: 1. Using the...
View ArticleComment on OpenPlant Modeler
Hello Amber, OpenPlant Modeler does report, but limited output only. However Scope of OpenPlant Orthographics Manager is growing, as it will furnish all the possible details which is required as an...
View ArticleComment on OpenPlant Orthographics Manager
Its a recent release product sometime in November. It is consistently growing and promising software. We will keep updating the wiki for new features getting added recently. Regards, Rahul Kumar
View ArticleComment on OpenPlant Orthographics Manager
Hello Amber, Try below link, which will guide you to offer some courses: learn.bentley.com/.../ViewLearningPathWithMasterCourseExpanded ;mcId=101650 Also check:...
View ArticleForum Post: RE: Instrument support tee stand, graphics or units problem for...
Hello Yogesh, Could you please let me know what version you are using? As well are you using Tee Stand dialog to input stand size or values are read from specification? Could you please send me...
View ArticleWiki Page: ProjectWise Node in Project Administrator is Greyed Out
Applies To Product(s): ProjectWise and Project Administrator Version(s): 08.11.09.140 Environment: N/A Area: N/A Subarea: N/A Original Author: Bentley Technical Support Group Overview Sometimes during...
View ArticleForum Post: RE: Instrument support tee stand, graphics or units problem for...
Hi Artiom J I am using Autoplant SS4 & default metric instrument spec i.e. Minstruments form Bentley. There are no AT_INSTTSTND components inside spec. I am using t stand dialog to input only...
View ArticleComment on OpenPlant Orthographics Manager
Rahul, Thank you! These links are exactly what I needed! -Amber Vick
View Article