Wiki Page: No loading of the tool pallets needed in AutoPLANT Piping.

$
0
0
Applies To Product(s): AutoPLANT Piping Version(s): 08.11.12.111 Environment: Windows Vista 64 bit Area: Open/Save Subarea: N\A Original Author: Berrie Geboers, Bentley Technical Support Group Problem No loading of the tool pallets needed in AutoPLANT Piping. Solution To prevent loading the tool pallets in a piping session take the following steps: · Close all Bentley applications. · Go in Windows Explorer to C:\Program Files (x86)\Bentley\Plant V8i\Support\ · Find the AT_START.LSP and copy it as a backup. · Open the original AT_START.LSP and find the (load "APRibbonCUI") section. · Comment out the lines (load "At_ToolPalettes") and (at_Remove_ToolPalette) with ;; · The result should be: (load "APRibbonCUI") ;;QK CUIX implementation.. ;;(load "At_ToolPalettes") ;QK First remove any loded palette path.. ;;(at_Remove_ToolPalette) · Save and close the lSP file. · Start up a new Piping session. See Also