Forum Post: View Markup Files in OpenPlant
Hi, I am creating markups in Navigator for viewing in OpenPlant. The computers with OpenPlant do not have Navigator installed and the model is not being dispayed in the markup. The model is missing...
View ArticleForum Post: RE: Valve Tag Name ERROR
Hello Harpreet & Tony, Thank you very much for your quick replies, I have tried both the options which was suggested by both of you, By applying Harpreet Suggestions : I was finding some errors...
View ArticleForum Post: Pressure drop in Piping model
Does Bentley have an application to give the details of pressure drop in Pipe runs in Piping model made from AutoPlant Modeller _SS_5 with Autocad_2012? Could Piping model be used in some Bentley...
View ArticleFile: AutoPLANT V8i (SELECTseries 7) ReadMe Files
To review the System Requirements, Enhancements and New Features, Known Issues, ProjectWise Integration etc. for the latest release, AutoPLANT V8i (SELECTseries 7), kindly use the attached zip file....
View ArticleForum Post: RE: Pressure drop in Piping model
Hi, PlantFlow used to import AutoPLANT models, and can be used for pressure drop calculations. Please contact your Account Manager for the latest version of PlantFlow that works with AutoPLANT SS5....
View ArticleForum Post: RE: Pressure drop in Piping model
Hello Tehreem, Please see the following WIKI about all things PlantFLOW's (i.e. import abilities, Overview, etc..) communities.bentley.com/.../7361.bentley-plantflow Regards, Mike Dattilio Bentley...
View ArticleForum Post: RE: Component description in 'linenumber' report
Hello Pradeep, This can be achieved please see below image which will help you. Disable the highlighted field check box. I hope this helps. Regards Dinesh
View ArticleForum Post: RE: Component description in 'linenumber' report
Hi Dinesh, It is working fine. Thanks for your reply.
View ArticleForum Post: Control Valves Actuator Orientation in Open Plant PowerPID
Hello, I have attached the image below where i have showed three images as : Image 1, Image 2 & Image 3, As you can see The Images, Can you please suggest me what i should do in class editor, so...
View ArticleForum Post: RE: Control Valves Actuator Orientation in Open Plant PowerPID
I have this same issue!
View ArticleWiki Page: Adding A New Descriptive Field To Updatable Component Data [TN]
Applies To Product(s): AutoPLANT V8i Version(s): 08.11.05.36 Environment: N/A Area: N/A Subarea: N/A Original Author: Jesse Wolfe, Bentley Technical Support Group Overview At times, you may want to add...
View ArticleForum Post: RE: Control Valves Actuator Orientation in Open Plant PowerPID
Krishnar, What version of OpenPlant PID are you running? Thanks Tony DeRosa Bentley Plant
View ArticleForum Post: RE: Valve Tag Name ERROR
Krishna, One thing to keep in mind - this will not allow for a dash or a space between the Device Type Code and Number. If either is placed you may get a sync error. Tony DeRosa Bentley Plant
View ArticleForum Post: RE: Control Valves Actuator Orientation in Open Plant PowerPID
Hello tony, I am using Bentley OpenPlant PowerPID V8i (SELECTseries 5) Regards, Krishna.
View ArticleWiki Page: How to force field weld component to appear under field materials...
Applies To Product(s): OpenPlant Isometric Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Reports Subarea: Original Author: Dinesh Solanki, Bentley Technical Support Group...
View ArticleForum Post: RE: Control Valves Actuator Orientation in Open Plant PowerPID
Krishna, From the menu select Help > About and get the exact number of the of the build. It should be something like 08.11.10.5xx. Thanks Tony
View ArticleForum Post: RE: Control Valves Actuator Orientation in Open Plant PowerPID
Krishna, This can be controlled by editing the schema. Load the OpenPlant_PID schema in the Class Editor and Supplement the schema with the OpenPlant_PID_Supplemental_Imperial schema. Locate the...
View ArticleForum Post: RE: What TrueType fonts does AutoPLANT (esp. P&ID) install? I...
Hello Dean, It seems that none of TTF are installed with AutoPlant. There are couple of SHX fonts in C:\Program Files (x86)\Bentley\Plant V8i\Support. But I could not find any footprints of TTF fonts...
View ArticleWiki Page: Not able to place 90 Degree Long/Short Radius reducing elbows
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Component Subarea: Original Author: Harpreet Singh, Bentley Technical Support Group Background When...
View ArticleForum Post: RE: OPPID SS3 Install
I am getting similar problem from yesterday, i am using ss5. Is there any option for again make it syncronise
View Article