Quantcast
Browsing all 16985 articles
Browse latest View live

Forum Post: Print Open plant specification detailed Report as Row Preview.

Hi, Can I print Open plant specification as a report like in Spec preview in each line of spec.? Preview spec shows me all information I filter from catalogue. This detailed report will be use for...

View Article


Forum Post: OPPID v.427 - Data Manager Connected Line/Equipment Issue

Hello there, Once I place an Instrument in OPPID and then synchronize the PID to Data Manager, this instrument works fine only if it is directly connected to the pipe run or equipment. However, if I...

View Article


Forum Post: Valve Tag Name ERROR

Hi, As a normal procedure of valve numbering in element information, i.e. after putting the Device Type Code - as "V" and Number as for example "2058". It does show correctly in the drawing screen, but...

View Article

Forum Post: RE: Valve Tag Name ERROR

Hi Krishna, It seems to be an issue with the regular expression on the NAME property. Could you provide the snapshot of expressions defined in the schema? Regards, Harpreet

View Article

Wiki Page: ProjectWise Integration

Key: CS – Client Server Article FAQ – Frequently Asked Questions TB – Technical Bulletin TN – TechNote VID – SELECTsupport Video Integration with Bentley ProjectWise - AutoPLANT Bentley Plant projects...

View Article


Forum Post: RE: OPM 383 Supports missing components in repository

The problem was resolved by deleting these components and redrawing them. It's highly probable that this was caused by the remove duplicates tool(recieved from bentley support) that we used to solve...

View Article

Forum Post: RE: OPM 383 Supports missing components in repository

Thanks for the update Jojje. Regards, Harpreet

View Article

Forum Post: RE: OPPID v.427 - Data Manager Connected Line/Equipment Issue

Fernando, I'm sorry that you are having this issue. Thank you for your detailed explanation as well. It seems that this is either a Relationship issue or a data mapping issue. Can you reply back here...

View Article


Forum Post: Component description in 'linenumber' report

Hi, This is regarding extraction of text description in excel file. We are using Bentley AutoPlant- piping. Component description of pipe displays as "PIPE, SCH 160, ASTM A 106 Gr.B PBE " while...

View Article


Wiki Page: Element info closed on element selection

Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX Environment: Windows 7 64 bit Area: Properties Subarea: Original Author: Harpreet Singh, Bentley Technical Support Group Problem...

View Article

Forum Post: What TrueType fonts does AutoPLANT (esp. P&ID) install? I want to...

What TrueType fonts does AutoPLANT (esp. P&ID) install? I want to use ICS and need to put the fonts on the ICS server. I could not tell by comparing the Window\Fonts folders of the server and my...

View Article

Wiki Page: How to configure OpenPlant to allow flange connection with...

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Component Subarea: Original Author: Harpreet Singh, Bentley Technical Support Group Background...

View Article

Forum Post: RE: Barcode

Hi, Susanna. I wonder do you have any good suggetions of fine Barcode scannners whose prcessing way is simple and fast. I want to classify my CDs by reading barcode . Any suggestion will be...

View Article


Wiki Page: How to Differentiate Between Multiple Records for Topworks in Spec.

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Component Subarea: Original Author: Harpreet Singh, Bentley Technical Support Group Scenario: When...

View Article

Wiki Page: How to change the precision level of Length on PIPE component

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Component Subarea: Original Author: Harpreet Singh, Bentley Technical Support Group Background This...

View Article


Forum Post: RE: Valve Tag Name ERROR

Hi Harpreet, Please refer below snap

View Article

Forum Post: RE: Valve Tag Name ERROR

Hi Krishna, Since there is no delimiter in the EC Expression, therefore regular expression is failing to calculate the property correctly. I am assuming that device type code in your case will be one...

View Article


Wiki Page: How to edit the DB3 files in AutoPLANT SS4

Applies To Product(s): AutoPLANT Piping Version(s): 08.11.09.140 Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: Original Author: Dinesh Solanki, Bentley Technical Support Group...

View Article

Forum Post: RE: Valve Tag Name ERROR

Hi Krishna, You could also make the Parser Regular Expression as follows: ^(? [\D]*)(? .*) the [\D]* following Device Type Code is used to specify NON-NUMERIC characters and this allows a Device Type...

View Article

Wiki Page: OPPID - Tag Expression and results

Tag number parsing and the results. These are defined in the OpenPlant_Supplemental_Tagging schema. Class ANNOTATION_COMPONENTS ECExpression...

View Article
Browsing all 16985 articles
Browse latest View live