Krishna, This can be controlled by editing the schema. Load the OpenPlant_PID schema in the Class Editor and Supplement the schema with the OpenPlant_PID_Supplemental_Imperial schema. Locate the INLINE_CONTROL_VALVE class. On the Properties tab select the MIRROR_ENABLED_LOCAL_Y property. Override the property. Set the Default Value field in the Property Custom Attribute to True. Save the schema. When you place the valve you will be prompted to select which side of the valve (inlet or outlet) that you want the actuator on. Next the rotation will take over and allow you set the valve on either side of the pipeline. The rotation is available in OpenPlant PID build 08.11.10.523. I hope this helps, Tony DeRosa Bentley Plant
↧