Forum Post: RE: Adding a user column in Data Manager (View)
I have tried the above suggestions to add a column to a view in Data Manager but it is not working. AutoPlant V8i SS4 08.11.09.140; SQL Server 2008; Access 2010 I want to add a COST field to the Valve...
View ArticleForum Post: RE: Automatic/Scheduled i-model creation from OPM files
Jojje , there is ProjectWise Wikis that could help you wit configuration. communities.bentley.com/.../15213.application-integration As well the whole section for Bentley i-model Composition Server...
View ArticleForum Post: RE: Automatic/Scheduled i-model creation from OPM files
Thanks Artiom! I will post further questions in the content publishing forum. If anybody would like to know the Openplant Automation extension is part of the Openplant Modeler installation. Don't...
View ArticleForum Post: Default Settings
Where do I find the settings for tagging valve sizes and the placement of those tags. I need to have them placed as shown in the picture but by default they want to place inside the top works of the...
View ArticleForum Post: RE: Default Settings
Hi Jeremy, You can change the Placement count to 1 in annotation custom attribute on SIZE property of FLUID_REGULATOR class as shown below: This setting will allow you to place the size tag wherever...
View ArticleForum Post: RE: Default Settings
Thank you Harpreet for the information Could you please direct me to where I might find that particular schema as I am not familiar with them just yet. I did use the Place Note when placing the leaders...
View ArticleWiki Page: DWG Mating flange rotation wrong
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.458 Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Technical Support...
View ArticleForum Post: RE: Default Settings
Please follow the steps below: 1. Launch Class Editor. 2. Load OpenPlant_PID schema from \Workspace\Projects\%Project_Name%\Dataset\Schemas location. 3. Right click on the schema and select Supplement...
View ArticleWiki Page: Map New AutoPLANT Relationship in OPIM Schema
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.XX.XXX Environment: Windows 7 32 bit, Windows 7 64 bit Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley...
View ArticleWiki Page: Missing EC_CLASS_NAME Data-AutoPLANT to OpenPlant Spec conversion
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: OpenPlant Specification Generator Subarea: - Original Author: Rahul Kumar, Bentley Technical...
View ArticleForum Post: RE: Default Settings
Thanks again Harpreet, I did fix the trailing leader issue by checking off the In-line Leader so that issue is solved. My other issue with the schema however is baffling. I proceeded to do the steps...
View ArticleForum Post: RE: Default Settings
Thanks for the update Jeremy! Please go through the link below: communities.bentley.com/.../19903.locate-missing-reference-schema-files-message-while-loading-schema-in-class-editor You will need to add...
View ArticleWiki Page: OpenPlant Specification Generator
See Also OpenPlant Modeler OpenPlant Modeler [FAQ] External Links Bentley Technical Support KnowledgeBase Bentley LEARN Server Comments or Corrections? Bentley's Technical Support Group requests that...
View ArticleForum Post: RE: Adding a user column in Data Manager (View)
Hello All. After your COST field has been added to the VALVE table, you may need to open your projects' PROJECT.MDB file in native Access and refresh the views. Open Windows Explorer and path to your...
View ArticleWiki Page: Line 241 Error-Launching OpenPlant Modeler
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: - Subarea: - Original Author: Rahul Kumar, Bentley Technical Support Group Overview While launching...
View ArticleWiki Page: Errors, Logs, Messages, Crashes - OpenPlant Modeler
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX & Others Environment: Windows 7 64 bit Area: - Subarea: - Original Author: Bentley Technical Support Group Errors/Logs/Message...
View ArticleForum Post: RE: Default Settings
Thank you for the information pertaining to the use of schemas, I was succesful at finding what you were refering to. My next question would pertain to the attribute, I am not seeing the same thing...
View ArticleForum Post: RE: Default Settings
SUCCESS!!! I found the missing link. Thank you so much Harpreet you have been more than helpful. I'm sure I will be speaking with you in the future as we are just in the starting process of using our...
View ArticleForum Post: Upcoming OpenPlant Virtual Classes: Week of April 27, 2015
OpenPlant Isometric Manager OpenPlant Virtual Classroom Apr. 28, 2015 8:30 AM – 5:00PM Dennis Roberts OpenPlant Modeler Fundamentals Imperial OpenPlant Virtual Classroom Apr. 28 – Apr. 30, 2015 8:30 AM...
View ArticleWiki Page: To Display Additional Material Information in Drawing and Reports...
Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: - Original Author: Bentley Technical Support Group Comments...
View Article