Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.458 Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: Original Author: Abhijit Bute, Bentley Technical Support Group Problem Description When generate isometric in dwg format sometimes user may face problem of mating flange rotation wrong. following illustrative steps helps to get correct flange orientation. Steps to Resolve Create the isometric in DWG as you do now Open it from OPIM Form the MS menu select File > Save As 4. Select the DWG output format and click the Options button. 5. In the general tab expand the Cells entry. 6. Uncheck “Create Single Block For Duplicated Cells” 7. Click on the save icon and save 8. Close the isometric and recreate the isometric Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧