Wiki Page: OpenPlant Orthographics Manager [FAQ]

What are the prerequisites required to install OpenPlant Orthographics Manager? To install OpenPlant Orthographics Manager, user should have Open Plant Modeler downloaded. What will be the least...

View Article


Wiki Page: How to Add New catalog data field in AutoPLANT Isometrics Bill of...

Background At times, user may want to add an additional field to isometric bill of material (i.e. Part Number, Vendor Catalog data etc.).following steps illustrate the procedures to add catalog field...

View Article


Wiki Page: Delete project from Document Manager.

Background Sometimes projects are delete from Project Administrator but in Document Manager still populate deleted project. Below illustrated steps helps you delete project from Document Manager. Steps...

View Article

Forum Post: RE: AutoPLANT V8i PIW menu not loading

I am glad I could help. Thanks & regards Dinesh

View Article

Forum Post: How to best handle the following type of equipment tag:...

How to best handle the following type of equipment tag: NNNN-TT-NNN, where N is a numerical and T a text? example: 1234-PMP-001 Thanks

View Article


Forum Post: RE: Open Plant Modeler / Spec generator: Valve with flanges...

Hi Jukka, Can you provide some more information on what you mean by a collar? I see in your image you have said that a lap-joint stub end is not the right fitting type here. Are the collars you refer...

View Article

Forum Post: RE: Heat Tracing Line thickness

Hi Artiom, Changed the following in the DDF file and it worked. Just one other question. Is is poosible to change the offset distance between the main pipe lin enad tracing? FITTINGS-GENERALN.S. INCH...

View Article

Forum Post: Upgrade AutoPLANT 8.06 to SS4

Hi, We have packaged AutoPLANT project which was originally done in AutoPLANT 8.06. Is it possible to unpack this project directly into SS4 and upgrade? Regards Ken

View Article


Forum Post: Is it possible for supports to use TAG as PIECE_MARK on isos...

by default PIECE_MARK seems to be automatically generated via the EBS file to create its own code. i would like this to use TAG field instead. is this possible?

View Article


Forum Post: RE: Upgrade AutoPLANT 8.06 to SS4

Hello Kfitz, I would like to point you to a good discussion on this topic which has happened before. Please refer below. I hope this helps....

View Article

Forum Post: RE: OPenPlant PowerPID "unhandled exception" error

This error at user end is resolved by installing the latest KKS workspace

View Article

Forum Post: RE: Open Plant Modeler / Spec generator: Valve with flanges...

Hello Ian, I do not know if both (lab-joint stub end or slip on flange) are not right ones for me (after searching web and seeing some images). Slip om flange: Lab joint flange: The loose flange with...

View Article

File: Flanges and collars for austenitic CrNiMo-pipes.pdf - 11/11/2014 6:21 AM

This attachment "Flanges and collars for austenitic CrNiMo-pipes.pdf" was uploaded on 11/11/2014 at 6:21 AM via email.

View Article


Forum Post: RE: Open Plant Modeler / Spec generator: Valve with flanges...

Hi Ian, As attached you will find flange tables for - Austenitic CrNi-pipes (stainless steel, AISI304) - Austenitic CrNiMo-pipes (stainless steel, AISI316) We very seldom use flange type 11, but it is...

View Article

File: Flanges and collars for austenitic CrNi-pipes.pdf - 11/11/2014 6:21 AM

This attachment "Flanges and collars for austenitic CrNi-pipes.pdf" was uploaded on 11/11/2014 at 6:21 AM via email.

View Article


Forum Post: RE: How to best handle the following type of equipment tag:...

Vacoas, For future reference it would be helpful for you to include the product and version you are using. Example: OpenPlant PowerPID SELECTseires5 Refresh3. I will assume you need this for OpenPlant...

View Article

Forum Post: RE: Open Plant Modeler / Spec generator: Valve with flanges...

Hi Jukka, For placement of auto flange, below are the two way you can do with flanges. A. Using AutoFlange table: - Enabling this option will place the valve without counter Flanges if there is no...

View Article


Forum Post: RE: Upgrade AutoPLANT 8.06 to SS4

thanks Dinseh,That refers to upgrade to XM, is it the same for upgrade to SS4?

View Article

Forum Post: RE: AutoPLANT V8i PIW menu not loading

Hi Dinesh, This is not fixed unfortunatley. I unloaded piw and pdw from my pc and just reloaded piw. Everything works fine on piw then. As soon as i reload pdw if I open piw it defaults to the pdw...

View Article

Forum Post: RE: [OPM V8i] Filter Specification dropdown

I have same problem. Can I use the custom attribute "External Database Query" linking to database and get data into field ? (The attribute is limited on OPID. ) Where can I get these information and...

View Article