Forum Post: Re: V8i P&ID, Drains and vents : major, minor or utility lines ?

Hello BobCorrect. By design, utility lines are unintelligent. The best way to handle inline components, such as the valves you mentioned, are to place the valves. CATT on them and fill out the desired...

View Article


Forum Post: AT_CADCOBJECT_EXTRUDE2

Hi All,I am using the at_CADCObject_extrude2, and am finding that I am not able to create an extruded shape with closed ends. I have tried setting the flag parameter to zero, 1 (AT_EXTRUDED_START_RIM),...

View Article


Forum Post: Re: Uploading Data sheet to Data Manager

I register the datasheet to an AT_tag type in Project Administrator.The cells that are linked are populated with information in the Excel sheet.The columns that have corresponding links in the...

View Article

Forum Post: Re: EQUIPMENT TANGENT LINE & CENTER LINE REF.IN ISOMETRIC

Thanks for reply, we tried it & its working. However i am getting the dimension from face of connected flange instead of face of equipment nozzle which means it is including gasket thickness which...

View Article

Forum Post: Re: Piping MTO with Line No. & Spec. at time.

YES .AUTOPLANT V8I SS2

View Article


Forum Post: EQUIPMENT TRIM ISOMETRIC

Dear sir,    While  extracting trim isometric we are getting number of sheets e.g.fitting connected to different nozzle is extracted in different sheets .We want trim isometric to be extracted in...

View Article

Image may be NSFW.
Clik here to view.

Blog Post: Error in Data Manager "The field could not be updated"

Error message in Document Manager and approach that was used to fix this issue.Below are the steps that where used to restore project functionality in this particular case and could wary from case to...

View Article

Image may be NSFW.
Clik here to view.

Wiki Page: Class Editor DynamicXMLSerializer Errors when supplementing OPPID

Description: Class Editor DynamicXMLSerializer Errors when supplementing OPPIDWhen supplementing the OpenPLANT_PID schema in Class Editor the following errors are received:2013-04-09 14:37:01,244 [1]...

View Article


Forum Post: AutoPlant ss3 win 7 64 bit and XP sharing project

Can someone let me know is there any issue with having an AutoPlant project have both XP stations setup with V8i 32 bit and Win 7 stations setup with v8i 64 bit accessing the same Sql project and...

View Article


Forum Post: Re: ATDB0719 Relationship Manager error code -213131

Thnx, it's useful advice for me) Just in my situation i changed value of Service!

View Article

Forum Post: Re: AutoPlant ss3 win 7 64 bit and XP sharing project

There were some issues in  AutoPlant 08.11.08.151 related to document open in 64 and 32 bit systems. If there is a way to avoid using different environment, possibly it would be the best. It seems this...

View Article

Image may be NSFW.
Clik here to view.

Forum Post: AutoPLANT V8i (SELECTseries 4) don't install autocad2012 xp sp3

Openation system is WINXP SP3AutoPLANT  V8i (SELECTseries 4)  AUTOCAD 2012office 2010but don't  installation

View Article

Image may be NSFW.
Clik here to view.

Forum Post: component preferences of autoplant is null

Openation system is WIN7 64bitoffice 2010AutoPLANT  V8i (SELECTseries 4) AUTOCAD 2012 component preferences of autoplant is null 

View Article


Forum Post: Re: AutoPLANT V8i (SELECTseries 4) don't install autocad2012 xp sp3

Hello , Please check that the MSVCR71.dll in is in: C:\Windows\System32This file is a part of .Net Framework. Search the pc for this file and copy it to the locations listed above.I case this is WinXp...

View Article

Forum Post: Re: OpenPlant PowerPID - Tag placement order

Hi TonyThanks for the feedback.  My question is a little bit different, I think.I have 2 separate properties that I want to automatically place with the symbol.  The positions cannot be automatically...

View Article


Forum Post: Re: ERROR LOGS ON SEWER CAD 5.5

Hi Tolu,Sewer CAD questions should be posted in the Hydraulics and Hydrology community as they are not Plant products and it is unlikely that anyone reviewing this group would have any knowledge of the...

View Article

Forum Post: Re: OpenPlant Isometric Configuration File

So are there any work arounds to be able to customise the isometrics?

View Article


Forum Post: Re: component preferences of autoplant is null

Is this appears in any project? Try to create new project and check comportment preferences availability. In addition try following: Set NETCONTROLS=0 in the C:\ProgramData\Bentley\Plant...

View Article

Forum Post: Re: OPPID: Creating relations when converting from PSPID

Hi Steve,I allready did that. I even created a complete new jsm object for a rupture disk. Still no relations...Any other suggestions?Kind regards

View Article

Forum Post: OpenPlant Power PID Place Instrument Parametric

HiHas anybody figured out or found a document on how the Place Instrument Parametric function works.  I am trying to get custom cells to work with the dialog box, but not having very much success.I...