Tag number parsing and the results. These are defined in the OpenPlant_Supplemental_Tagging schema.ClassANNOTATION_COMPONENTSECExpressionthis.GetRelatedInstance("PLANT_AREA_HAS_NAMED_ITEM:1:PLANT_AREA,...
View ArticleForum Post: Subtracting Solids
Hello All,I am seeing that AutoPLANT scripts are capable of extruding to produce a solid, but I am not able to find a method which will permit subtracting one solid from another. Am I overlooking a...
View ArticleForum Post: PSDS 08.09.04.63 How do I convert Column Line Reference data into...
All the information on the isometric is in millimeters except the column line refence information. I have tried updating the psiso.lib. Verifying design file units, jsm units and clinrefm.dat units all...
View ArticleForum Post: Re: OPPID : custom parametric equipment
Hi Steve,That explains a lot!Thank you.
View ArticleForum Post: Supports/Topworks Browser
Hi All,Has anybody had luck modifying the supports/topworks browser (content) in AutoPLANT V8i? We maintain our settings and projects on a server, and for whatever reason, the supports/topworks browser...
View ArticleWiki Page: OPPID - Ss5 Known Issues
Known Issues in OpenPlant PowerPID V8i (SELECTseries 5)V08.11.10Known Issues of Bentley OpenPlant PowerPID V8i (SELECTseries 5)When doing a File Compress never enable the 'delete empty cell headers'...
View ArticleForum Post: Re: OPPID - converting fittings
Good evening,Some update:I have tested with another fitting and I think that the problem lies in the relationship "RUN_HAS_IN_RUN" that is not formed, although it is defined in the jsm conversion class...
View ArticleForum Post: OPPID SS4 - Valves disconnecting from Pipeline
We are having issues with Valves disconnecting from Pipelines we suspect revisions but are not sure. The only way we see the disconnects is viewing in DataManager Valve List there we see the disconnect...
View ArticleForum Post: Re: OPM error message after upgrading to OPM SS5 pw ss4
Forgot the configvariables.Thank u Prashant!
View ArticleForum Post: Autoplant relationship manager
In AutoPLANT relationship manager can we lock relationhips like spool. Area.We can lock line number by right clicking on line numebr but for other relations can we lock by right clicking. or any...
View ArticleForum Post: OPM SS5- Custom Equipment and Named expression
Ive added a couple of rules for where(on what level) equipment should be placed using named expressions and Element templates. Currently im placing all my equipment on the same level as the name of the...
View ArticleForum Post: Re: OPM SS5 PWSS4 free document and free component
Nearly...Im able to free the document but not the components that where previously checked out to the file.Im trying to free the components via OPMOf course I can do this via the op administratorIf u...
View ArticleWiki Page: OPPID Dialog suppress
Project.pcfBMF_BORDER = NONEPID_SUPPRESS_STARTUP_DIALOG=1PLANT_PROJECT_BYPASS_PRIMARY_UNITS_CHECK=1 Bentley.ConversionServices.xmlTurn the prompting off <Extension Name="PSPID Conversion"...
View ArticleForum Post: Re: OPM SS5 PWSS4 free document and free component
Right......so when you check out components from OPMS and then check in the dgn file into the PW repository, the components remain locked in the dgn file. You can Free the components from OP...
View ArticleForum Post: Re: OPPID SS4 - Valves disconnecting from Pipeline
The Item Browser can be usedcommunities.bentley.com/.../leveraging-item-browser.aspx
View ArticleForum Post: Re: OPPID: converting valves from pspid
Wim Aerts,Try and verify the actual origin point of the valves in question. The Connect Points are in relation to the cell origin point.The XML files related to the respective cell libraries contain...
View ArticleForum Post: Re: OPM SS5 PWSS4 free document and free component
Ahaa seems like ive missed the " OpenPlant ModeleServer Operations History Tool"
View ArticleForum Post: Re: OPM SS5 dublicate GUID
Made a backup of the SQL. As a temporary fix ive deleted the affected pipelines in the SQL. The user will redraw these pipelines. The components are still in the database thou...so making a report for...
View ArticleForum Post: Re: OPPID: converting valves from pspid
Wim,Try creating a new pipeline in the same drawing and drag the problem valve from the existing converted pipeline to the newly created pipeline. How does this behave?Tony DeRosaBentley Plant
View ArticleWiki Page: ProjectWise Node in Project Administrator is Greyed Out
Document InformationDocument Type: TechNote Product(s): ProjectWise and Project AdministratorVersion(s): 08.11.09.140Original Author: Bentley Technical Support Group OverviewSometimes during...