Quantcast
Browsing all 16985 articles
Browse latest View live

Forum Post: Re: OPIM Label (PartID, CutID, etc) offset in isometrics

Thank you for answering this. Personally I would like to see this an option we can control.Ken

View Article


Forum Post: Re: HOW TO CREATE USER DEFINED SUPPORT

Dear Dinesh  sir,Thanks for your reply,We tried however we are facing error as below .Thanks in advanceRegards,Shrinivas Jadhav

View Article


Forum Post: Re: AP V8i SS3 SpecGen: ComponentOne trial periode expired

Sorry, I just realized that this has been adressed in another thread: communities.bentley.com/.../89917.aspxIssue closed.Best regardsHenrik

View Article

Forum Post: Isogen Excel Mapping from 2 Different Sheets In 1 Workbook Using...

I am trying to combine to of out excel lists into 1 worksbook with 2 sheet tabs. We have modified our ebs file to map the information from 1 sheet, and now we would like to mapp additional information...

View Article

Forum Post: OPM Schema Customization Using Value Maps

Good day,I have 2 questions related to the use of value maps in the OP3D, Modelling & ModellingViews schemas.Background.Using configuration manager you can set specific values for insulation...

View Article


Forum Post: Re: isogen not using custom skey for dummy legs

Thanks for the feedback.Looks bit tricky with supports attached to custom dummy legs. Default actual symbol 01HG is blank for dummy legs, and dummy leg is described in PCF as pipe.When we force to use...

View Article

Forum Post: Re: How to control wrench orientation

Hello, Unfortunately, it seems this is not possible as wrench operator's handle has no direction defined in PCF file. Regards, Artiom

View Article

Forum Post: [OPM V8i] Filter Specification dropdown

I want to filter the value visible in the Specification dropdown using the value of another property.I have the property A with value "AA", i want to see in the list of Specification only value that...

View Article


Blog Post: How to set all components to existing at one go?

Often we think of a way through which componets could be set to existing at one go.The first way of doing this is to edit component and do it the other wat is to load at_bonus.mnu and use this utility...

View Article


Forum Post: Re: Openplant Isomanager and posting Isosheet to PW

Are there any schemas/setup files to modify how Isomanager post files/folders to PW? Primary I would like to be able to post the GUID of the OPM isosheet to the PW isosheet...this to get a relationshop...

View Article

Image may be NSFW.
Clik here to view.

Wiki Page: Adding “Existing” attribute to component preferences menu

   Applies To    Product(s):AutoPLANT Piping Version(s):N/A Environment: N/A Area: Settings/Attributes Subarea:  Original Author:Artiom Jakubovic, Bentley Technical Support Group         The following...

View Article

Image may be NSFW.
Clik here to view.

Wiki Page: AutoPLANT Piping

Key:CS – Client Server ArticleFAQ –  Frequently Asked QuestionsTB – Technical Bulletin TN – TechNoteVID – SELECTsupport VideoAutoCAD-Based Piping Design and Modeling SoftwareAutoPLANT Piping gives you...

View Article

Forum Post: Model file name sent to Isogen pcf file

I am trying to get a model file name to export into the Isogen pcf file. I'm not having any success. Has anyone tried to do this? I'm familiar with editing the opcfhdr.ebs file. However, I'm a piping...

View Article


Image may be NSFW.
Clik here to view.

Wiki Page: Components Are Not Updating When Using Update From Spec [TN]

   Applies To    Product(s):AutoPLANT Piping Version(s): 08.09.xx.xx, 08.11.xx.xx Environment: N/A Area: N/A Subarea: N/A Original Author:Richard DeLong, Bentley Technical Support Group...

View Article

Forum Post: Re: Insulation Linetype

Line type can be changed by Opening Project Administrator> Piping>Preferences>Line Type

View Article


Image may be NSFW.
Clik here to view.

Wiki Page: Creating Isometrics of more than one Line number using AutoISOGEN

Applies To    Product(s):AutoPLANT Piping Version(s):08.11.08.151, 08.11.09.140 Environment: N/A Area: General  Original Author:Dinesh Solanki, Bentley Technical Support Group         Creating...

View Article

Forum Post: Re: Model file name sent to Isogen pcf file

Thank you for feedback. Glad to hear it worked.According to Isogen Info document there is :-92  *  CLIENT-DRAWING-IDENTIFIER variable that could be used in POS files as well. Regards, Artiom

View Article


Forum Post: Effect of opening any Autoplant 3D piping drawing in “Read-only”...

Dear Bentley Team, A > If we open any Autoplant 3D piping drawing in “Read-only” mode then, what will be its effect on its other related files, its MS-Access databases, it’s any xref links, etc...

View Article

Forum Post: How to convert ACIS 3D Model to the STEP Model?

Dear Bentley Team, We want to convert ACIS 3D Model to the STEP Model. Please let me know whether it can possible? If yes, then Please let me know Procedure for converting ACIS 3D Model to the STEP...

View Article

Image may be NSFW.
Clik here to view.

Wiki Page: How do I purchase AutoPLANT applications?

   Applies To    Product(s):AutoPLANT Modeler Version(s): Environment: N/A Area:  Subarea: N/A Original Author:Keith Couvillion, Bentley Technical Support Group           How do I purchase AutoPLANT...

View Article
Browsing all 16985 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>