Forum Post: RE: Is there any documents regarding to OPM piping catalogue

Hi, There is no such document as of now. Are you looking for dimensional data for components as shown below? You can see this in catalog editor in OP SpecGen. Regards, Harpreet

View Article


Forum Post: RE: AutoPLANT: How to change the spec name for all inserted...

This is what I´ve received from TSG when asking for this - it worked for me :) There is an old Lisp routine in the C:\Program Files (x86)\Bentley\Plant V8i\Bonus\ folder called SPCUPD.LSP that can be...

View Article


Forum Post: RE: OPPID: Line Breaks on Fittings and Valves

How to change the default settings of "use predefined points for range" that is "False"-by default as "True" (comes under the "Scematics components custom attributes" tab

View Article

Wiki Page: How to Populate Class Name on Components

Applies To Product(s): OpenPlant PID Version(s): 08.11.10.XXX Environment: Windows 7 64 bit Area: Properties Subarea: Original Author: Harpreet Singh, Bentley Technical Support Group Problem...

View Article

Wiki Page: AutoPLANT P&ID Conversion

AutoPLANT P&ID Conversion

View Article


Wiki Page: OpenPlant Orthographics Manager [FAQ]

Applies To Product(s): OpenPlant Orthographics Manager Version(s): V8i Environment: N/A Area: N/A Subarea: N/A Original Author: Bentley Technical Support Group What are the prerequisites required to...

View Article

Forum Post: RE: OPPID: Line Breaks on Fittings and Valves

Hi Krishna, You need to right click on Class name. Select Custom Attribute>Add/Remove option and then add 'Schematics Component Custom Attribute'. Once the attribute is added you can set it to TRUE...

View Article

Comment on OPPID - Annotation

Hello, Can you please tell me how to show a "Secondary Description Tag" for an equipment in OpenPlant PID like it use to show in AutoPlant PID. Regards, Krishna Natkar.

View Article


Forum Post: RE: Is there any documents regarding to OPM piping catalogue

Thanks, I am looking for the value for END_COND of clamp connection. And user want such a document for building cata...

View Article


Forum Post: RE: Is there any documents regarding to OPM piping catalogue

Please refer to the below link which will help you. communities.bentley.com/.../21149.openplant-end-condition-long-descriptions Regards, Harpreet

View Article

Wiki Page: How to Auto-Place Victaulic coupling on pipe to pipe connection

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: Component Subarea: Original Author: Harpreet Singh, Bentley Technical Support Group Background By...

View Article

Comment on OPPID - Annotation

Hello Krishna Natkar, I suggest posting questions like this in the Forum section of this community and not the Wiki section. By default, equipment prompts the user to place to tags - a primary and a...

View Article

Wiki Page: Total Weight in Bill of Material Using AutoPLANT Modeler

Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.458 Environment: Windows 7 64 bit Area: Settings/Attributes Subarea: N\A Original Author: Kestutis Mitkus, Bentley Technical...

View Article


Forum Post: What criteria is used by OPM to select compatible bolts \ gaskets?

Some of our connections are returning bolts, some aren't. Is it size+end prep+ facing, or some other combination?

View Article

Forum Post: RE: What criteria is used by OPM to select compatible bolts \...

Hi Dave, You could check the Facing of the component and the mating flange as well. Check below variable in your project pcf file OPM_MATCH_PROPERTY_MAP_FACING If the facings do not exist in the pcf...

View Article


Forum Post: RE: What criteria is used by OPM to select compatible bolts \...

Hello Dave, You can send some examples to investigate further, like Flange type details, Bolt types etc. Regards, Rahul Kumar

View Article

Wiki Page: How to set Priority For Selected Branched Components present in...

Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 64 bit Area: OpenPlant Specification Generator Subarea: - Original Author: Rahul Kumar, Bentley Technical...

View Article


how to install autoplant ss4 for acad1012 and autoplant ss6 for acad 2014 on...

how to install autoplant ss4 for acad1012 and autoplant ss6 for acad 2014 on the same computer with only 1 startup (no dual boot) in Plant Design and Engineering

View Article

Comment on how to install autoplant ss4 for acad1012 and autoplant ss6 for...

Hello, I would say it is not possible as same AutoPlant product generations (V8i) share to many common data (reg key, classes... etc...). So unfortunately I don't see a way to achieve this. Regards,...

View Article

Forum Post: RE: OPM HVAC Takeoff components

Thanks Tony!

View Article