Forum Post: RE: What criteria is used by OPM to select compatible bolts \ gaskets?

$
0
0
Hi Dave, You could check the Facing of the component and the mating flange as well. Check below variable in your project pcf file OPM_MATCH_PROPERTY_MAP_FACING If the facings do not exist in the pcf file, then you need to add it. Also, try running connectivity checker to see what message you get for joints in question. Regards, Harpreet