Forum Post: Openplant Modeler schemas in regular Microstation

Hi! I wonder if its possible to view(Element information) openplant modeler component properties in microstation without creating a i-model. I think I want to load openplant schemas in regular...

View Article


Forum Post: RE: Settings for P&ID

Hello, I will try to answer your 3 question now and check up on others later on. In order to customize Process's Tag number follow steps below: Open Project Administrator > PROJECT_NAME> Database...

View Article


Forum Post: RE: Schema Differencing - How Are You All Coping??

Hi Brent, I feel your pain... Well, part of it anyway. I've recently finished updating our OPM build to 440. I knew the Schema Differencing tool wasn't all that great, but I'd hoped that with 440...

View Article

Forum Post: RE: Schema Differencing - How Are You All Coping??

I totally agree with all your comments Scott & Brent. When I started implementing OPM late last year it quickly dawned on me this was going to be an administration nightmare. There needs to be...

View Article

Forum Post: Autoplant Project Admin - error creating project

Hi, I created an autoplant project (V8i SS4) on a cloud server through project admin and connectied it to a SQL database on another server. Everything seemed to run ok but I got an error right at the...

View Article


Forum Post: RE: Settings for P&ID

Thanks. Ok, works. But... 1. When I want choose SPEC from my spec for Project, I see only Bentley Specs: 2. After settings parameters in "Enter Tag Number" windows (in P&ID) I can't get...

View Article

Forum Post: RE: Autoplant Project Admin - error creating project

Hello kfitz, Please refer below wiki which will help you solve the issue....

View Article

Forum Post: RE: Openplant Modeler schemas in regular Microstation

Hi Jojje, I tried to follow the steps in the above link but I get an error when I import OpenPlant_3D schema with ECX schema import key-in. May I know why do want to load OpenPlant Schemas in...

View Article


Wiki Page: How to Hide Valve Flange Line for Flanged End Condition

Applies To Product(s): Bentley OpenPlant PowerPID Version(s): 08.11.10.XXX Environment: Windows 7 64 bit Area: Component Subarea: Graphics Original Author: Harpreet Singh, Bentley Technical Support...

View Article


Forum Post: RE: Settings for P&ID

Hello Dmitry, Thank you for your questions. The specifications by default are loaded from %LOCAL_ROOT%\Specs\PROJECT_UNITS. This can be changed editing value in AP Config. This dialog can be accessed...

View Article

Forum Post: RE: Openplant Modeler schemas in regular Microstation

Yes ive also tried loading the schemas unsuccesfully. Even tried to export the schemas from a i-model and load those schemas instead. Did'nt work! But it should work. No I do not want to edit the OPM...

View Article

Forum Post: RE: AutoPLANT SS4 Custom Support graphics

Hello Ken, I have created Service Request based on this post. You should receive notification email with Defect number. One again Thank you for collaboration and sorry for inconvenience you have faced....

View Article

Comment on Customize Pipeline Annotation to Include Service & Insulation...

Is there away to remove the Area from the label on the (CAD) PID but have the Area visable to the user for input so it can be placed in the database?

View Article


Forum Post: OPPID - access to properties from VBA

Good afternoon, I have a drawing in PowerPid with components who have properties assigned to them. I would like to have access to these properties from within a VBA routine, is that possible? Kind...

View Article

Forum Post: RE: OPPID - access to properties from VBA

All properites in the Element information dialog are accessible throu the "Propertyhandler" object if thats what u are asking. I think theres several threads about this in the Microstation Programming...

View Article


Comment on Customize Pipeline Annotation to Include Service & Insulation...

By following the steps in this posts, you can create your own pipeline annotation. Could you please tell me what is your pipeline TAG?

View Article

Forum Post: RE: OPPID - access to properties from VBA

Good morning, I have been looking around in the programming sections and I found some suggestions. The problem is that the OPPID is a complex environment with a lot of ECXML files. This is the...

View Article


Forum Post: RE: OPPID - access to properties from VBA

Good morning, I am feeling a bit like an idiot right now. I did my testing with standard Microstation in stead of PowerPid. After I used the propertyhandler API in PowerPid I could see all the...

View Article

Forum Post: OPPID key-in for select parent?

Hello all, Since 08.11.10.523 regular selection only selects the element you actually selected and you have to use the select parent command in the context menu to get the "old selection behavior" (or...

View Article

Forum Post: RE: OPPID key-in for select parent?

Hi Koert, There is no key-in command for selection of parent elements. As of now the only way is to select from context menu. Regards, Harpreet

View Article