Applies To Product(s): Bentley OpenPlant PowerPID Version(s): 08.11.10.XXX Environment: Windows 7 64 bit Area: Component Subarea: Graphics Original Author: Harpreet Singh, Bentley Technical Support Group Background This article explains how to hide the Flange line on the valves which have flanged end condition. Since there is no direct setting or configuration variable to hide the flange line display, therefore user need to remove the end condition graphics from Schema which will be explained below. However, user also have the flexibility to choose the end condition as NONE which will show the same result, but this article complies only to the above condition i.e. hide flange line when the end condition is flanged. Steps to Accomplish Launch Class Editor and load OpenPlant_PID.01.04 schema. Supplement OpenPlant_PID_Supplemental_Imperial schema. Go to FLANGED_VALVE_END_CONDITION class and remove Valve.cel library from Schematics CAD Custom Attribute as shown below: Save the changes in schema and verify the result in OPPID. Comments or Corrections? Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!
↧