Wiki Page: AutoPlant Modeler SS5 installation issue

Applies To Product(s): AutoPLANT Modeler Version(s): Environment: Windows 7 64 bit Area: N/A Subarea: N/A Original Author: Artiom Jakubovic, Bentley Technical Support Group Problem Description Installation of AutoPlant Modeler SS5 fails with following error message: Failed to create an instance of the Bentley Security object This issue take place when AutoPalnt Modeler SS5 is installed on a system that had AutoPlant PDW SS4 installed. Therefore some of the AutoPlant PDW SS4 folder should be removed manually. Steps to Resolve From AutoPlant Modeler readme (ftp://ftp.bentley.com/pub/help/bentleyautoplantmodeler/081110182en/readme.htm) Installation Notes section: Recommended method: It is recommended to completely uninstall existing AutoPLANT V8 i applications before installing AutoPLANT V8 i (SELECTseries 5). Please make sure that the below mentioned folders are clean (if exists). Windows 7 (64 bit) C:\Program Files (x86)\Bentley\Plant V8i\ C:\Program Files (x86)\Common Files\Bentley Shared\Plant V8i\ C:\ProgramData\Bentley\Plant V8i\ Windows 7 and XP (32 bit) C:\Program Files\Bentley\Plant V8i\ C:\Program Files\Common Files\Bentley Shared\Plant V8i\ C:\ProgramData\Bentley\Plant V8i\ (in Windows 7) and C:\Documents and Settings\All Users\Application Data\Bentley\Plant V8i\ (in Windows XP)