Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.574 Environment: Windows 7 (64 bit) Area: Settings\Attributes Subarea: - Original Author: Dinesh Solanki, Bentley Product Advantage Group Background Normally, any loose component changes to field because it does not need to work in shop. However, you can control this separately for pipes and fittings by modifying below settings from style.cfg. This will work with both AutoPLANT Modeler & OpenPlant Isometrics Manager & OpenPlant Modeler & OpenPlant Isometrics Manager. Steps to Accomplish Launch Isometrics Configuration Dialog. Navigate to Advanced Node. Click on "Explore style" option. Navigate to Config folder & open Style.cfg file. Search IE_LooseFittingToField in this file. Check for default fitting settings as IE_LooseFittingToField = 1. This will enable any loose field fitting to appear in field material under BOM. Ensure the variable to be set as "1" to appear in BOM under Field Category. Save the changes and Generate the Isometrics & verify Results. Notice below image the elbow comes under field material. Check Another Case When Field Fit weld has been assigned to particular set of flange or in any case the weld has been categorized to Field, it produces different Part ID under field Material. See image below: To consolidate the material as one quantity, you need to set the variable present in Style.cfg file as IE_LooseFittingToField = 0. (Use same steps as discussed above). See image below after modification: See Also Comments or Corrections? Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!
↧