Wiki Page: Browse Limit in PowerPID tag browse dialog – hits limit when tags exceed 2000

$
0
0

  
 Applies To Tag Browse Dialog
  
 Product(s):OpenPLANT PowerP&ID
 Version(s):08.11.10.38 and greater
 Environment: N/A
 Area: 
 Subarea: 
 Original Author:Bentley Technical Support Group
  

 

 

 

 

 

 

 

 

Purpose: Browse Limit in PowerPID tag browse dialog – hits limit when tags exceed 2000

  

BriefDescription: Once the database gets over 2000 tags the browse alternative repository will come back with the error message seen below.

 

 

To overcome this simply add the BMF_BROWSE_PROPMPT_LIMIT variable to the PCF or UCF file and set it for a value greater than the number given in the message.

Example:

BMF_BROWSE_PROPMPT_LIMIT = 5000

 